GUIDE TO INSTALLATION AND OPERATION
30
| IRD-3811
Overload Cursor (dB)
: The overload cursor appears on the meter as an arrowhead in
the meter scale. The two pulldown boxes set the position of the overload cursor on the
left and right meters (the range of values shown in the pull-down list depends on the
type of meter selected).
Meter functionality:
•
The meter is divided into three zones:
•
The dividing points are specified in the Upper Zone Limits and Lower Zone
Limits boxes. Click in the box and scroll to the desired value.
•
The color of the meter in each zone is selectable. Click on the colored square
corresponding to the zone to open a color selection dialog.
•
The level at which the channel is to be considered in Overload can be specified
using the Channels Overload boxes. Click in the box to see a scrollable list, and
select the desired level.
•
The Overload Counter shows a running count of the number of overloads detected.
•
The Phasemeter is a small meter that represents the phase correlation factor
between the two channels of a pair.
180°
90°
0°
3.4.15 The Network Settings panel
This panel is only available when the ETH Option has been activated.
Settings tab
ETH Port Status
The status of the ethernet link is shown by the icons:
•
Link is down (red)
•
Link is OK (green)
NOTE: This is the equivalent to the green LED on the rear-
panel ETH connector.
ETH Port Direction
Use the pulldown to select the Ethernet port functionality.
Options are:
•
Disabled – not functional
•
Input – receives a transport stream
•
Output – sends transport stream
IP Config
This section displays the current IP settings on the right, and
provides data boxes to enter new values on the left.
Figure 3.29 Audio meter configuration
Figure 3.30 Network Settings panel – Settings tab