30
Malfunction
Cause
Remedy
Check power supply.
Renew the PCB.
If the thermal switch operates re-
peatedly contact Kohler Mira for
further advice.
Drip from shower
head.
Solenoid valve defec-
tive.
Renew the solenoid assembly.
Renew the PCB.
Isolating valves
closed.
Inlet filters blocked.
Check valve fitted in-
correctly.
Appliance sited above
cold water storage cis-
tern.
Plumbing system fault
(airlock).
Blocked spray plate.
Open valves.
Clean filters.
Refer to "
Maintenance: Inlet
Manifold, Check Valve
".
The appliance is not suitable for
negative head installations. Refer
to "
Installation Requirements
".
Reroute the pipework to avoid
airlock.
Clean spray plate. Refer to the
Installation and User guide supplied
with the
shower fittings
.
Pump speed does
not change.
Low or no water flow.
Pump does not op-
erate.
PCB failure.
Electrical supply failure.
PCB failure.
Motor overheated, ther-
mal switch operated.
Pump does not stop.
Microswitch failure.
PCB failure.
Renew the harness assembly.
Renew the PCB.