10. Solenoid Valve Assembly – Removal and Installation
The following procedure can be applied for replacing the solenoid valve assembly.
Warning!
Before proceeding turn off the electrical and water supplies. The electricity
supply must be turned off at the mains and, if applicable, the appropriate circuit fuse
removed. Mains electrical connections are exposed when the cover is removed.
Caution!
Disconnect wiring by pulling only on the body of the spade connector and not
the wire itself.
10.1.
Follow instructions
9.1.
to
9.5.
in the "
Maintenance
" section to remove the
damping vessel.
10.2.
Disconnect the solenoid valve
wiring connections.
10.3.
Unscrew the screw securing the
solenoid valve clamp bracket with
a T10 torx screwdriver and remove
the clamp bracket.
10.4.
Remove the solenoid valve
assembly.
Caution!
Before refitting
components ensure the 'O' seals
are fitted to the inlet and outlet of
the solenoid valve assembly.
10.5.
Refit the components in reverse
order.
10.6.
Commission the Mira Extreme,
refer to "
Commissioning:
General Commissioning
".