4. Installation Diagrams
To prevent operational difficulties, the feed from the cylinder should be as illustrated
below. Side entry cylinder bosses are not recommended because:
•
A drop in cylinder water level could expose a top entry immersion element if
fitted.
•
Air-in-water solution gathers at the edge of the cylinder and in the centre, during
the heating process before travelling up the vent.
D.H.W.
60
o
C
A high level hot feed pipe run as illustrated below will result in air locking and should
be avoided.