8.
Refit the control knob (with the override button at the bottom), control knob retaining
screw/plastic override stop and concealing cap.Please ensure the plastic override
stop is correctly seated.
Note!
Do not overtighten the control knob retaining screw. Internal components may
be damaged if the screw is overtightened.
9.
This completes the procedure for
Commissioning: "Adjustable Maximum
Temperature Setting”
.
Concealing
Cap
Control Knob
Plastic
Override
Stop
Control Knob
Retaining Screw
Adjustable
Temperature
Stop
Temperature
Override Button
To
decrease
the temperature, reposition the stop one serration
clockwise
.
Repeat the check as necessary.