Reversed Outlet Connection
Mira CombiForce 415 shower controls are supplied with inlet connections
hot left,
cold
right
and
bottom outlet
. The Mira CombiForce 415B is supplied with inlet connections
hot left
,
cold right
and
top outlet
as
standard
.
To reverse the outlet position:
1.
Rotate the shower control body through 180
o
and install the shower control.
2.
Prise off the concealing cap, unscrew the control knob retaining screw and remove
the temperature override stop and control knob.
3.
Remove the D-shaped hub fitted to the spindle. Rotate the spindle one full turn (360
o
)
and refit the hub.
4.
Remove the adjustable temperature stop and turn over. Make sure that the
Max
o
C
with the indentations side is uppermost. Adjust the maximum temperature stop
(refer to
Commissioning
).
5.
Refit the control knob assembly (with the override button at the bottom) and turn the
knob fully clockwise to the shut off position.
6.
This completes the procedure for
“Reversed Outlet Connection”
.
Cover Shroud
Cover Shroud
Retaining Screws
Concealing
Cap
Adjustable
Temperature Stop
Hub
Control Knob
Plastic
Override
Stop
Control Knob
Retaining Screw
The hub is 'D' shaped. This
ensures the hub is fitted in the
correct position.
Spindle
Skid Washer
Summary of Contents for Combiforce 415