18
Back Inlet Supplies
1.
Follow the shower control installation
procedure as for
“Rising or Falling
Inlet Supplies”: instructions 1.
to
4.
inclusive.
2.
Using a spirit level, mark the route of
incoming hot and cold water supply
pipes at a distance of
153 mm
centres.
3.
Remove the plaster and brickwork to the
required depth to conceal the supply
pipework.
Note!
Depth must be sufficient to prevent
pipe concealing plates fouling on the
plumbing elbows.
4.
Install the hot and cold water supply
pipework ensuring that the pipe ends
emerge from the wall surface at
153 mm
centres, and project from the finished
wall surface by
13 mm
. Allow for two
circular recesses measuring
32 mm
diameter x
10 mm
depth, to accept the
two pipework concealing plates.
5.
Make good the wall surface.
Fit the pipework concealing plates over
hot and cold water supply pipework.
Backplate
Concealing
Plate
32 mm
13 mm from
finished wall
surface
10 mm minimum
between elbow
and finished wall
surface.
153 mm
Circular
Recess
Elbow