14
1.
Before you decide on the final position
of your shower control, please bear in
mind the following:
- Decide on a suitable position for
the shower control. The position
of the shower control and the
shower fittings must provide a
minimum gap of
25 mm
between
the spill-over level of the shower
tray/bath and the handset. This
is to prevent backsiphonage.
- Determine whether the hot or
cold water services will be
connected to the shower control
from the bottom (rising) or from
the top (falling).
7
Installation
Section
Falling Supplies
Rising Supplies
25 mm
Minimum
Spill-over Level
Hose Retaining
Ring
Mira CombiForce 415 Surface Mounted Shower Control
Rising or Falling Inlet Supplies
Note!
The Mira CombiForce 415 is supplied with inlet connections
hot left
,
cold right
and
bottom outlet
as standard. For installations with reversed hot and cold supplies
complete the installation and refer to
the section
Installation: "Reversed Inlet
Supplies".