FrameMaker Ver.5.5E(PC) Di151 TROUBLESHOOTING
00.03.10
T-16
(7)
C1200: System Memory Failure
C1300: Polygon Motor Malfunction
C133B: Option Communications Error
C13F0: SOS Detection Failure
C1468: Hardware (EEPROM) Malfunction
• These malfunctions are detected mainly when there is a fault occurring in software, hard-
ware, or communications.
Code
Action
C1200
1. Reset the malfunction.
2. If the malfunction is detected again, check the Control Board and Memory
Board for proper connections.
3. If connections are okay, change the Control Board and/or Memory Board.
C1300,
C13F0
1. Reset the malfunction.
2. If the malfunction is detected again, check the harness between, and PJ con-
nections on, the PH Unit and Master Board.
3. If connections are okay, change the PH Unit and Master Board.
C133B 1. Reset the malfunction.
2. If the malfunction is detected again, check the Control Board and the control-
ler board.
3. If connections are okay, change the Control Board and the controller board.
C1468
1. Run “FA” of Function.
2. If it has not been checked okay (“FF” appears on the display), change the
EEPROM on the Control Board. If it has been checked okay (“00” appears on
the display), change the Control Board itself.