FrameMaker Ver.5.5E(PC) Di151 TROUBLESHOOTING
00.03.10
T-12
(3)
C0200: HV Output Failure
C0200
Relevant Electrical Parts
High Voltage Unit HV1
Master Board PWB-A
Step
Check
Result
Action
1
High Voltage Unit operation: the voltage across
PJ4A-4 on the Master Board and GND is DC24
V after the malfunction has been reset.
YES
Change High Voltage Unit.
2
Proper connection between the High Voltage
Unit and Master Board.
YES
Change Master Board.
NO
Correct connection.
PJ4A-1(DC5V)
PJ4A-2(SS_H/L_CTL)
PJ4A-3(T_VR)
PJ4A-4(HV_REM)
PJ4A-5(T_MON)
PJ4A-6(B_MON)
PJ4A-7(B_REM)
PJ4A-8(C_REM)
PJ4A-9(C_MON)
PJ4A-10(GND)
PJ4A-11(DC24V)
PWB-A
Drum
Charg
Developing
Bias
Seal
Bias
Toner Blade
Bias
Image Transfer
PJ10HV-11
PJ10HV-10
PJ10HV-9
PJ10HV-8
PJ10HV-7
PJ10HV-6
PJ10HV-5
PJ10HV-4
PJ10HV-3
PJ10HV-2
PJ10HV-1
HV1
4007C09TAB