FrameMaker Ver.5.5E(PC) Di151 TROUBLESHOOTING
00.03.10
T-10
3-2.
Troubleshooting Procedures
(1)
C0000: Main Motor’s Failure to Turn
C0000
Relevant Electrical Parts
Main Motor M1
Master Board PWB-A
Step
Check
Result
Action
1
Main Motor turns after the malfunction has
been reset.
NO
Correct drive.
2
Main Motor operation: the voltage across
PJ6A-3 on the Master Board and GND is DC5
V (motor deenergized) and DC0 V (motor ener-
gized) after the malfunction has been reset.
NO
Change Master Board.
3
The voltage across PJ6A-4 on the Master
Board and GND is DC5 V (motor deenergized)
and DC0 V (motor energized) after the mal-
function has been reset.
YES
Change Master Board.
NO
Change motor.
M1
PJ3
1
2
3
4
PJ6A-1(GND)
PJ6A-2(DC24V)
PJ6A-3(M1 ON)
PJ6A-4(M1 LOCK)
PWB-A
4007C06TAB