FrameMaker Ver.5.5E(PC) Di151 DIS/REASSEMBLY, ADJUSTMENT
00.03.21
D-33
(4)
CD Registration Adjustment (Paper Tray)
Requirement
NOTE
This adjustment must be made whenever the PH Unit is replaced.
Procedure
1. Produce a test pattern (F5: Test Pattern 1).
2. Fold the test pattern in half and make sure that the centerline on the test pattern is
aligned with the crease. If it is not aligned with the crease, perform the following adjust-
ment procedure.
3. Enter Adjust function A9.
4. Change the setting value using the 1Key or 10Key as necessary (1 step equivalent to
0.5 mm).
If the centerline deviates on the B side, increase the setting value.
If the centerline deviates on the A side, decrease the setting value.
✽
If one adjustment sequence does not bring the centerline into the required range, per-
form the sequence again.
5. Press the Start key to validate the setting value.
NOTE
If the Clear/Stop key is pressed to go back to the Basic screen without pressing the Start
key, the setting will be restored to the original value.
Requirement
Adjust Mode Function
Setting Range
CD registration
adjustment
43 to 57
(-3.5 to +3.5 mm)
4007D050AA
B Side
A Side