FrameMaker Ver5.5E(PC) Di151 SWITCHES ON PWBs/TECH. REP. SETTINGS
2000.02.03
S-16
Choice Code
Setting (The default is
).
C6
<Data Clear>
Use to clear the counters and initialize the various types of setting
data.
<Procedure>
1. Using the 10Key and 1Key, select the desired function.
2. Press the Start key to validate the selected function (counter or
setting data).
3. Turn OFF and ON the Power Switch. (This completes the clearing
of the data.)
NOTES
• “9” or “A” can be selected when the Auto Exposure Mode key is
pressed.
• “A” is selected when clearing all counters at once (C6-1 to -7).
C8
<Exposure Lamp OFF Time Setting>
Select the time it takes the Exposure Lamp to turn OFF after a copy
cycle has been completed.
Highlighted
Data
Description
Data
Description
0
None
7
PM counter
1
I/C counter
8
Use’s/Tech. Rep. Choice
4
Misfeed counter
9
Adjust
5
Copy counter
A
All counters
6
PC print counter
Data
1
2
Description
30 sec.
20 sec.
3 min.
0