34
Chapter 6. Machine adjustment and setting up
GB
6.2.4. Summary of configurable variables
(AUTOMATIC and MANUAL programs)
SIDE
TEMPERATURE [C]
> 185 <
BELTS
SPEED [ %]
> 100 <
PHOTOCELL
SELECTION
> 0 <
PHOTOCELL
ACTUATION [mm]
> 0 <
REAR
FILM [mm]
> 50 <
PHOTOCELL
DELAY [mm]
> 0 <
FILM
LOOSENING [mm]
> OFF <
UNWINDER
DELAY [s]
> 0.02 <
MULTIPLE
PACKAGING
> OFF <
BELT STOP
AT SEALING
> OFF <
STOCK OF
MANUFACTURES
> OFF <
START
WITH PEDAL
> OFF <
Range: 0 ÷ 300.
Default: 25.
Range: 0 ÷ 900.
Default: 50.
Range: 0 ÷ 100.
Default: 100.
Range: O, V, O +V.
Default: O.
Range: 0 ÷ 250.
Default: 0.
Range: 0 ÷ 100.
Default: 0.
Range: 1 ÷ 250.
Default: OFF.
Range: 0.00 ÷ 1.00.
Default: 0.02.
Range: OFF, ON.
Default: OFF.
Range: 0 ÷ 230.
Default: 185.
Range: OFF, ON.
Default: OFF.
Range: 10 ÷ 10000.
Default: OFF.
MARK
READOUT
> OFF <
FUNCTION
QUALIFICATION
> ON <
BELT
REVERSAL [mm]
> OFF <
PACKET
LENGTH [mm]
> OFF <
PUNCH
> OFF <
Range: 1 ÷ 600.
Default: OFF.
OPTIONAL
Range: OFF, ON.
Default: OFF.
OPTIONAL
Range: OFF, ON.
Default: OFF.
Range: 1 ÷ 500.
Default: OFF.
STOP
AUTOMATIC / MANUAL
XXXXXXX
FRONT
FILM [mm]
> 25 <
SEALING
TIME [s]
> 1.2 <
Range: 0.0 ÷ 3.0.
Default: 1.2.
FRONT
TEMPERATURE [C]
> 185 <
Range: 0 ÷ 230.
Default: 185.
BELT
APPROACHING
> OFF <
SEALING
TIME [s]
> 1.2 <
SIDE
TEMPERATURE [C]
> 185 <
FRONT
TEMPERATURE [C]
> 185 <
BELTS
SPEED [%]
> 100 <
UNWINDER
DELAY [s]
> 0.02 <
OPTIONAL
Range: OFF, ON.
Default: OFF.
Range: OFF, ON.
Default: OFF.
STOP
AUTOMATIC
STOP
MANUAL
Range: USER 1, USER
Default: USER 1
TYPE OF MENU
> USER 1 <
TYPE OF MENU
> USER 1 <
2
Range: OFF, ON.
Default: OFF.
S: XXX.X
F: XXX.X
XXXXXXX
S: XXX.X
F: XXX.X
XXXXXXX
S: XXX.X
F: XXX.X
Summary of Contents for Pratika 56 CS Series
Page 108: ...107 7 4 ...
Page 109: ...108 7 4 ...
Page 110: ...109 7 4 ...
Page 111: ...110 7 4 ...
Page 112: ...111 7 4 ...
Page 113: ...112 7 5 ...
Page 114: ...113 ...