Page 49 of 50
AN-49-003 Rev.: E (September 6, 2019) M175867 (R95153) File: AN49003.doc
This document and its contents are the property of Mini-Circuits
3.12.5
The Trigger Out
of the SSG models is normally
‘0’ and rises to ‘1’ (3.3V) whenever a Trigger
Out is required
. The signal then drops back to ‘0’ (0V) after a few milliseconds.
3.12.6
When a “Trigger In” option
is selected, the SSG models will trigger at a rising edge. The
SSG will register a trigger as short as 100 nSec.
3.12.7
During Internal Pulse modulation
SSG-6000RC and SSG-6001RC produce a trigger out
at the start of every pulse automatically.