Dynamic pulse mode (SSG-15G-RC only) :
This mode, currently available only in the SSG-15G-RC allows setting a sequence of up to 100 different
pulses with pulse width, pulse period and RF signal power and frequency set individually for each signal. To
start this mode click on the dynamic pulse button and a new window will open.
Figure 3.7.5a
Dynamic pulse mode button
Enter in the new window the parameters of the signals you wish to run, then select ‘run continuously’ to
have the sequence run repeatedly until stopped, or enter the number of times you wish it to run, and click
‘Run’. The sequence of signals will begin to run.
Note:
Pulse width can be set as low as 0.1µs, however performance may degrade at low pulse width.
Please check datasheet for limits of guaranteed performance.
Figure 3.7.5b
Dynamic pulse mode window