AN-48-003 Rev. H (Jun 09, 2022) This document and its contents are the property of Mini-Circuits ECO-013719 Page 23 of 44
Notes:
1) To refresh the list of units found click on the Search button.
2) The search function uses ports UDP 4950 and UDP 4951 for communication, ensure
your firewall allows access to these ports.
3) For Peak power sensor models you need to enable Ethernet control before using it for
the first time see
section 3.1.12
3.2.3
After entering the IP address,
enter your password if you set one (see
section 3.1.10
), select the communication protocol you wish to use (HTTP or Telnet) and
click start, the unit's main screen will open.
Note:
changing Ethernet settings is only possible via USB control, see
section 3.1.8
3.2.4
Telnet or HTTP commands can
also be used to control the power sensor
without using the GUI. Just type in the command in the address field of your Internet
browser, implement a Get/Post HTTP function in your selected application (for HTTP) or
establish a Telnet connection (for Telnet). A full list of the commands available and their
syntax is available in the PWR models programming handbook.
Note:
Depending on the browser used and your network configuration you may need to disable
the proxy server for your computer or add the smart power meter's IP address to the list of
addresses in the proxy server.