25
With 2 stations shared (this equipment
→
master station)
Device no.
Details
Classification
RXn0
1) Setting value write response (response 1)
Communication
RXn1
㻌
RXn2
2) General command response (response 2)
RXn3
3) Readout/write selection response (R/W response)
RXn4
4) Mode-switching response (response 3)
RXn5
RXn6
5) Normal CPU operation
RXn7
㻌
RXn8
6) Decimal point display position 1
RXn9
6) Decimal point display position 2
RXnA
6) Decimal point display position 4
RXnB
㻌
RXnC
㻌
RXnD
㻌
RXnE
㻌
RXnF
㻌
RX(n+1)0
7) PEAK
Basic signal
RX(n+1)1
7) MEAS
RX(n+1)2
7) END
RX(n+1)3
7) CHECK
RX(n+1)4
7) HOLD
RX(n+1)5
7) MULTI (multimode is used)
RX(n+1)6
7) EXECUTE (measurement in the multimode)
RX(n+1)7
7) OK
RX(n+1)8
7) NG
RX(n+1)9
7) Upper/lower limit
RX(n+1)A
7) S0
RX(n+1)B
7) S1
RX(n+1)C
7) S2
RX(n+1)D
RX(n+1)E
8) Weighing capacity over
RX(n+1)F
9) Faulty weight
RX(n+2)0
10) Calibration number
10
0
1
RX(n+2)1
2
RX(n+2)2
RX(n+2)3
RX(n+2)4
RX(n+2)5
RX(n+2)6
RX(n+2)7
~
RX(n+3)0
Reserved system area
RX(n+3)1
RX(n+3)2
RX(n+3)3
RX(n+3)4
RX(n+3)5
RX(n+3)6
RX(n+3)7
RX(n+3)8
㻌
RX(n+3)9
11) Initial data setting complete flag
RX(n+3)A
12) Error status flag
RX(n+3)B
13) Remote ready
RX(n+3)C
RX(n+3)D
RX(n+3)E
RX(n+3)F
n:
Value determined by station number setting
*
Faulty weight is set to ON due to errors other than measurement sequence
errors.