16
(3) Remote register
With 4
stations shared (this equipment
→
master station)
Station
Remote
register
Details Notes
1
RWrn
1) Peak value
RWrn+1
RWrn+2
2) Track value
RWrn+3
2
RWrn+4
Undefined
RWrn+5
Undefined
RWrn+6
3) Error code
RWrn+7
4) Auxiliary error code
3
RWrn+8
9) Calibration number (lower 8
bit)
RWrn+9
Undefined
RWrn+A
RWrn+B
4
RWrn+C
5) General data area
RWrn+D
RWrn+E
6) Command no. (response)
RWrn+F
7) Operating mode (response)
n: Value determined by station number setting
With 2 stations shared (this equipment
→
master station)
Station
Remote
register
Details Notes
1
RWrn
8) Indicated value
(peak/track value)
RWrn+1
RWrn+2
3) Error code
RWrn+3
4) Auxiliary error code
2
RWrn+4
5) General data area
RWrn+5
RWrn+6
6) Command no. (response)
RWrn+7
7) Operating mode (response)
n: Value determined by station number setting
With 1 station shared (this equipment
→
master station)
Station
Remote
register
Details Notes
1
RWrn
8) Indicated value
(peak/track value)
RWrn+1
RWrn+2
3) Error code
RWrn+3
4) Auxiliary error code
n: Value determined by station number setting
Summary of Contents for CC-Link CSD-709-73
Page 1: ...DIGITAL PEAK HOLDER CC Link Interface CSD 709 73 Instruction Manual EN294 1701 ...
Page 2: ......