— CAL
— LIN
Selects the scale which is to be linearized and
starts linearization. Initiates a linearization
procedure for WP1
— WP 1
Initiates a linearization procedure for WP1
This procedure is interruptable by the
(Exit) Button.
The weight values are fix.
— WP 2
Only visible if there is a second scale defined
in menu
Initiates a linearization procedure for WP2.
This procedure is interruptable by the
(Exit) Button.
The weight values are fix.
— GEO
— END
Leave menu level
If a metric unit (kg or g) is used for the normal weighing then the calibration unit is kg =
kilo gram.
Linearization weights are fix. There are three points: zero, 0.5 * MaxLoad, Maxload.
Procedure is nearly the same as for Calibration. Only Display-Weight shows [LIN]
9.2.2
Menu Settings
CAL.ADJ
9.3
Geographical Factor Adjustment Procedure
The Geographical Adjustment Factor [GEO] is used to adjust the calibration based on the
current location. (Settings from 0 … 31 are available). Refer to table
to determine the
GEO factor that corresponds to your location.
Enter into Menu Mode:
After WP1 or WP2 (if present) was activated
Weight
Second menu level = Calibration
Piece Weight
Third menu level = here WP1
Count
blinking first weight value
The Displays show:
1.
Press and hold the
button long.
9 Calibration and Adjustment
Compact Scale Puro® Count
Minebea Intec
EN-61