Model Number
XL3050A
Type
open chassis
AC Line Voltage
115 VAC/230 VAC, ±10%, 50/60 Hz, single phase
Line Fuse Rating
10 A
Horsepower Range @ 130 VDC Output
1/8–1/2 HP
Horsepower Range @ 240 VDC Output
1/4–3/4 HP
Form Factor
1.05
Maximum Armature Current
5 ADC
Field Voltage @ 115 VAC Input
50 VDC/100 VDC
Field Voltage @ 230 VAC Input
100 VDC/200 VDC
Maximum Field Current
1 ADC
Maximum Armature Voltage Adjustment Range @ 115 VAC Input
55–150 VDC
Minimum Armature Voltage Adjustment Range @ 115 VAC Input
0–65 VDC
Maximum Armature Voltage Adjustment Range @ 230 VAC Input
55–240 VDC
Minimum Armature Voltage Adjustment Range @ 230 VAC Input
0–65 VDC
Acceleration Time Range (with no load)
1–12 seconds
Deceleration Time Range (with no load)
coast to a stop–12 seconds
Speed Adjustment Potentiometer
10K ohms
Analog Signal Voltage Range (signal must be isolated; S1 to S2)
for 0–130 VDC Armature Voltage
0–2.7 VDC
for 0–240 VDC Armature Voltage
0–5.0 VDC
Approximate Input Impedance (from S1 to S2)
100K ohms
Speed Regulation (at base speed)
1%
Vibration
0.5G max (20–50 Hz)
0.1G max (>50 Hz)
Safety Certification
UL Recognized Component, file E132235
CSA Certified Component, file LR41380
4
Specifications
Summary of Contents for XL1100A
Page 69: ...63 NOTES...
Page 70: ...64 NOTES...