![MIMAKI ML Tiger-1800B MKII Operation Manual Download Page 164](http://html.mh-extra.com/html/mimaki/ml-tiger-1800b-mkii/ml-tiger-1800b-mkii_operation-manual_1800296164.webp)
Chapter 9 MAINTENANCE
9-20
5 31
2
0531:09(ZZZZZZZZ)INKTANK SENSOR
ZZZZZZZZ indicates a path number.
1 : Path 1
2 : Path 2
:
8 : Path 8
Error in the balance of
the ink supply unit
Check that the ink tank is
correctly set, that there is no
impact, and that there is no
load.
Turn off the power of the
internal PC and then the
main power of the machine in
this order, and then turn on
again after a while.
If the problem persists even
after performing the above
operations, contact your local
distributor, our sales office, or
service center.
5 4A
2
054A:YY(________)PDC POSINT:1234
PDC position interrupt
does not occur.
An error occurred in the
linear scale or Y motor.
Turn off the power of the
internal PC and then the
main power of the machine in
this order, and then turn on
again after a while.
If it appears again, contact
your local distributor, our
sales office, or service
center.
Ink
6 01
0
0601:09(ZZZZZZZZ)INK NEAR END
ZZZZZZZZ indicates a path number.
1 : Path 1
2 : Path 2
:
8 : Path 8
Ink in the ink tank is
low.
Ink is low.
Replace it with a new ink tank
according to the following
procedure.
1. Pull out the tank tray.
2. Replace with a new ink
tank.
3. Return the tank tray.
4. Execute [CLEAR ALARM].
6 02
1
0602:09(ZZZZZZZZ)INK END
ZZZZZZZZ indicates a path number.
1 : Path 1
2 : Path 2
:
8 : Path 8
Ink in the ink tank is run
out.
6 03
1
0603:09(ZZZZZZZZ)INK TANK SET
ZZZZZZZZ indicates a path number.
1 : Path 1
2 : Path 2
:
8 : Path 8
Ink tank is not detected.
Follow the steps below to set
the ink tank.
1. Pull out the tank tray.
2. Set the ink tank.
3. Return the tank tray.
4. Execute [CLEAR ALARM].
If the above does not solve
the problem, contact your
local distributor, our sales
office, or service center.
6 17
2
0617:09(ZZZZZZZZ)WRONG SUBTANK
SENSOR
ZZZZZZZZ indicates a path number.
1 : Path 1
2 : Path 2
:
8 : Path 8
Detected an
abnormality of the sub-
tank liquid level sensor.
Turn off the power of the
internal PC and then the
main power of the machine in
this order, and then turn on
again after a while.
If it appears again, contact
your local distributor, our
sales office, or service
center.
Error
No.
Error
level
Error displayed
Cause
Measures
Summary of Contents for ML Tiger-1800B MKII
Page 3: ...ii 1 2 2 4 5 6 ...
Page 6: ...v Troubleshooting 9 5 Dismantling 9 27 ...
Page 25: ...Chapter 1 Introduction 1 19 1 2 3 4 5 6 M915601 PC outlet rated label ...
Page 26: ...Chapter 1 Introduction 1 20 ...
Page 38: ...2 12 Chapter 2 Outline explanation ...
Page 50: ...4 10 Chapter 4 Installation ...
Page 120: ...Chapter 6 Basic usage 6 66 ...
Page 140: ...Chapter 7 Operation Adjustment and Maintenance 7 20 ...
Page 174: ... MIMAKI ENGINEERING CO LTD 2020 IG MM Tiger Products Install Pack 2 04 ...