Chapter 8 Safety Devices and Residual Risks
8-2
Safety Devices
Emergency switch
Press the emergency switch to immediately stop any operation in progress and deactivate the controls (Emergency
condition).
Warning light tells you whether the emergency switch is enabled or not. Warning light lights up to discover the emergency
situation that occurred. To recover from an emergency, turn and release the emergency switch clockwise until the beep
sounds.
Follow the procedure indicated below in order to reset the emergency switch.
Passive safety device
The passive safety device eliminates the risk of the operator. This risk varies depending on the targeted processing. This
system reduces the risks that could not be eliminated at the design stage of this machine to an acceptable level and
reduces the operator's active intervention required for preventive measures of the machine.
The main passive safety devices installed on the machine are:
Protective guard for mechanical parts of the machine: Prevents contact between the operator and the mechanical parts of
this machine.
Hazard identification pictogram: Draws attention points that the operator should pay attention to dangerous parts of this
machine.
• Mimaki is exempt from any responsibility for injury or damage to the parts when operating the machine in
the absence of necessary safety conditions such as removing or passing through the safety guard.
• Mimaki is exempt from any responsibility for injury or damage to parts when improper mechanical
changes are made to this machine or its parts.
• Mimaki is exempt from any responsibility for injury or damage to parts when using this machine for the
purposes different from its machine design or the machine at purchased.
• The customer is obliged to inform Mimaki in case of defect and / or malfunction of the protection systems
and any potentially dangerous situation.
Procedure
Reset of emergency switch
S
Mode
Key
Indication
Feature
Reference
1
AUT.
P01 - No.3
Reset emergency
When the warning light is on, the emergency
switch is activated.
2
Check which push button was pressed. Removed
the cause of the emergency.
3
PEM
[EMERGENCY]
Turn and release the emergency switch clockwise
until the beep sounds.
4
P01 - No.3
Reset emergency Press the emergency reset switch until it turns off.
5
AUT.
The warning light turns off indicating the reset of
the emergency switch.
End of procedure
• The customer is obliged to inform Mimaki in case of defect and / or malfunction of the protection systems
and any potentially dangerous situation.
Summary of Contents for ML Tiger-1800B MKII
Page 3: ...ii 1 2 2 4 5 6 ...
Page 6: ...v Troubleshooting 9 5 Dismantling 9 27 ...
Page 25: ...Chapter 1 Introduction 1 19 1 2 3 4 5 6 M915601 PC outlet rated label ...
Page 26: ...Chapter 1 Introduction 1 20 ...
Page 38: ...2 12 Chapter 2 Outline explanation ...
Page 50: ...4 10 Chapter 4 Installation ...
Page 120: ...Chapter 6 Basic usage 6 66 ...
Page 140: ...Chapter 7 Operation Adjustment and Maintenance 7 20 ...
Page 174: ... MIMAKI ENGINEERING CO LTD 2020 IG MM Tiger Products Install Pack 2 04 ...