© 2009 MIMAKI ENGINEERING CO.,LTD.
8.5.2
P.2
8.5.2 #TEST
#MOTOR TEST
TAKE-UP MOTOR <ent>
#TAKE-UP MOTOR
RUNNING
#TAKE-UP MOTOR
START
:ent
#HEATER TEST
TEMPERATURE
<ent>
[FUNCTION] / [
] / [
]
#TEST
HEATER TEST
<ent>
[
] / [
]
PRE PRT AFT
35C 35C 35C
35C 35C 35C
(35C 35C 35C)
[
] / [
]
#HEATER TEST
SSR
<ent>
<15F> <15F> <15F>
OFF OFF OFF
PRE PRT AFT
35C 35C 35C
#WARMING TEST
OFF [ C] ( 20 C)
#TEST
WARMING TEST
<ent>
[
] / [
]
#TEST
ACTION TEST
<ent>
#ACTION TEST
VACUUM FAN
:LOW
#ACTION TEST
Y-CUTTER
:OFF
#ACTION TEST
LED POINTER
:OFF
#ACTION TEST
DEOD. FAN
:OFF
#ACTION TEST
DRY FAN
:OFF
HDC FAN1 : HDC FAN2
ON : ON
#ACTION TEST
PR SOLENOID
:OFF
[
] / [
]: Changes items in a loop.
#ACTION TEST
P.HEAD SOLENOID :OFF
#ACTION TEST
VACUUM FAN
:LOW
#TEST
SENSOR TEST
<ent>
[
] / [
]
#SENSOR TEST
SET LEVER
:ON
#SENSOR TEST
R.PAPER
:OFF
#SENSOR TEST
Y-ORIGIN
:OFF
#SENSOR TEST
WIPER
:OFF
#SENSOR TEST
FRONT COVER
:ON
#SENSOR TEST
HEAD HEIGHT
:OFF
#SENSOR TEST
PR SENSOR
:OFF
This screen can be displayed by
pressing [FUNCTION] on any
screen.
#SENSOR TEST
CUT HEAD JOINT :OFF
#SENSOR TEST
PRT.HEAD JOINT :OFF
[JOG]: Changes items in a loop.
The items are displayed in the order shown in Sensor Test Menu. ON = o, OFF = x
L : SET LEVER
P : R.PAPER
Y : Y-ORIGIN
W : WIPER
H : HEAD HEIGHT
PR : PR SENSOR
CJ : CUT HEAD JOINT
PJ : PRT.HEAD JOINT
L=o P=o Y=x W=x
H=o PR=x CJ=x PJ=o
#SENSOR TEST
Head Voltage
:700
#SENSOR TEST
Main PCB ID
:800
#OPTION / REEL = ON
EXH.= ON DRY = ON
#TEST
OPTION
<ent>
[
] / [
]
#TEST
KEYBOARD LED
<ent>
HEAT:ooo CONST.:ooo
PRINT :o CUT :o
[
] / [
]
#TEST
KEYBOARD TEST <ent>
#KEYBOARD TEST
Key-> NONE
[
] / [
]
#TEST
LCD TEST
<ent>
!!!!!!!!!!!!!!!!!!!!
""""""""""""""""""""
#KEYBOARD TEST
Key-> [USER TYPE]
#KEYBOARD TEST
[END]->END TEST
Displayed corresponding to a
pressed key.
[
] / [
]
R.1.0
Maintenance Manual > Operation Flow > Service Mode > #TEST
Model CJV30/TPC Issued 2008.08.04 Revised
F/W ver. 1.00 Remark
1.0