Maintenance Manual > Test Items > Other Test > Checking Conduction of HDC FFC COM Line
Model CJV30/TPC Issued 2009.06.30 Revised 2010.11.05 F/W ver. 2.50 Remark
1.1
5.2.5 Checking Conduction of HDC FFC COM Line
Outline
Check whether the HDC FFC COM line has disconnection or poor contact or not.
After turning off the sub and main power switches in order, unplug the power code.
Check if no electric charge is remaining in the PCB.
Refer to the "4.5.2 Electric charge checking when replace the Electrical Parts"
It is very dangerous if sleep mode functions mistakenly during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also there is a possibility of electric shock because of high power voltage applied the high-pressure part
of the power supply PCB assy. Take care to avoid contact with it.
M
Y
K
C
C
K
Y
M
M
Lc
Y
M
C
K
C
Lm
M
Y
Lc
W
C
K
Lm
W
Signal
Test pin on the
ink slider PCB
Test pin on the
main PCB
Normal conduction
Nozzle line
COM-A
TP6
TP1
Less than 3 ohms
A*
COM-B
TP7
TP2
Less than 3 ohms
B*
COM-C
TP8
TP3
Less than 3 ohms
C*
COM-D
TP9
TP4
Less than 3 ohms
D*
COM-E
TP10
TP5
Less than 3 ohms
E*
COM-F
TP11
TP6
Less than 3 ohms
F*
COM-G
TP12
TP7
Less than 3 ohms
G*
COM-H
TP13
TP8
Less than 3 ohms
H*
4-color ink set
6-color ink set
6-color + white ink set
A line C line E line G line
B line
D line F line H line
A line C line E line G line
B line
D line F line H line
A line C line E line G line
B line
D line F line H line
* See below about nozzle lines.
M
C
Y
K
Lk
Lk
Lm
Lc
M
C
Y
K
S
W
Lm
Lc
7-color ink set
8-color ink set
A line C line E line G line
B line
D line F line H line
A line C line E line G line
B line
D line F line H line