© 2009 MIMAKI ENGINEERING CO.,LTD.
7.1.2
P.6
7.1.2 List of Error Messages
207
ERROR 207
SLEW RATE
Trouble with COM wave
1. Restart
2. Upload event log
3. Report what it happened to
SIGN&GRAPHIC, SG DESIGN GROUP
ERROR 207
OVERFLOW
ERROR 207
UNDERFLOW
208
**** ERROR208 ****
CHECK MAIN PCB ID
The device type ID of the main PCB is different.
Check the device type ID switch of the main PCB.
211
ERROR 211
HeaterTEMP(--/--/--)
An abnormal temperature of the media heater was
detected.
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Replace the main PCB assy. (
2. Replace the power supply PCB assy.
(
3. Replace the relevant platen cover with a new
one.
ERROR 211
HeadWARM.TEMP.(----)
An abnormal temperature of the head heating
heater was detected.
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Make sure that the connection to the main FPC
is correct.
2. Replace the relevant head heating heater with a
new one.
3. Replace the ink slider PCB assy. (
)
ERROR 211
HeadWARM.BREAK(----)
The head heating heater is disconnected.
* This error is never displayed when no head warm
heater is installed.
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Replace the relevant head heating heater with a
new one.
2. Replace the ink slider PCB assy. (
)
ERROR 211
HeadWARM.THERM(----)
Trouble has occurred with the thermistor of the
head heating heater.
* This error is never displayed when no head warm
heater is installed.
250
ERROR 250
Y COORDINATES
An error was detected during scanning operation. Turn off the main power, and turn it on a little later.
If such an abnormality recurs, check the uploaded
parameter and the status of use, then report them to
the Development Division.
251
ERROR 251
SYSTEM ERROR
System error
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Check whether no abnormality is found by
examining the memories (Main.FROM).
2. In case the error recurs, check the uploaded
parameter and the status of use, and then report
them to the Development Division.
List of error messages (6/6)
Error
No.
Indication on LCD
Cause
Remedy
R.1.3
Maintenance Manual > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model CJV30/TPC Issued 2008.08.04 Revised 2010.11.05 F/W ver. 2.50 Remark
1.3