![MIMAKI CJV30 Series Maintenance Manual Download Page 140](http://html1.mh-extra.com/html/mimaki/cjv30-series/cjv30-series_maintenance-manual_1800148140.webp)
© 2009 MIMAKI ENGINEERING CO.,LTD.
5.1.9
P.1
R.1.0
Maintenance Manual > Test Items > Test Function > [MOTOR TEST] PUMP MOTOR
Model CJV30/TPC Issued 2008.08.04 Revised
F/W ver. 1.00 Remark
1.0
5.1.9 [MOTOR TEST] PUMP MOTOR
Function
Operation test of pump motor is executed.
Operation Procedures
Step
Item
Description
Remarks
1
Pump selection
[
], [
]: Selects pump by moving the cursor.
[
], [
]: Selects operation.
[
], [
]:
Selection of item 1–3
2
Rotation direction
designation
[
], [
]: Selects pump rotation direction.
Set value: FORWARD, REVERSE
3
Driving speed designation
[
], [
]: Selects driving speed.
Set value: 100–4000pps (unit: 100pps)
4
Carriage/Motor state
selection
[FUNCTION]:Carriage/motor state at test selection menu is
displayed.
<Carriage> IN: Executes at cap position.
OUT: Executes after carriage out.
<MOTOR> ON: Executes with Y-axis motor ON.
OFF: Executes with Y-axis motor OFF.
5
Test start
[ENTER]: Removes the cap and moves the carriage to
maintenance position. Drives the pump motor with
designated conditions.
[END]: Ends the test.
During operation, open/
close the cartridge valve
with [FUNCTION].
6
End
Test is completed.
Note that executing (FORWARD) while the cap is on causes vacuum suction.