background image

4

5

OPERATION

WARNING

Always remove battery pack before 

changing or removing accessories. 

Only use accessories specifically recommended 

for this tool. Others may be hazardous.

To reduce the risk of injury, wear safety goggles 

or glasses with side shields. Always wear leather 

gloves.

Operating the Trapsnake™ Driver

Using the forward/reverse switch:

1. For 

forward

 (clockwise) rotation, push in the forward/

reverse switch from the right side of the tool ►. Check 

the direction of rotation before use.

2. For

 reverse 

(counterclockwise) rotation, push in the 

forward/reverse switch from the left side of the tool 

◄. Check direction of rotation before use. 

3. To 

lock 

the trigger, push the forward/reverse switch 

to the center position. The trigger will not work while 

the forward/reverse switch is in the center locked 

position. Always lock the trigger or remove the bat-

tery pack before performing maintenance, changing 

accessories, storing the tool and any time the tool is 

not in use.

Starting, stopping and controlling speed:

The Trapsnake™ driver may be used at any speed from 

0 RPM to full speed.

1. To start the Trapsnake™ driver, insert an M12™ 

battery and pull the trigger.

2. To vary the driving speed, increase or decrease pres-

sure on the trigger. The further the trigger is pulled, 

the greater the speed.

3. To stop the tool, release the trigger.

APPLICATIONS

WARNING

Always remove battery pack before 

changing or removing accessories. 

Only use accessories specifically recommended 

for this tool. Others may be hazardous.

To reduce the risk of injury, wear safety goggles 

or glasses with side shields. Always wear leather 

gloves.

Inserting Auger into Drain

1. Unclip the cable from the cable clip.

2. Pull the cable sleeve back so that only the cable tip 

is visible at the boot. 

3.  Carefully insert the boot into the drain, tilting the 

auger for easy entry.

 

WARNING!

 The boot must be in the drain to support 

the cable from whipping. The cable can damage 

porcelain.

4. If using the Trapsnake™ driver, set the forward/

reverse switch to the forward position ►. Pull the 

trigger while pushing down on the driver to advance 

the cable into the drain. If using the auger handle, 

rotate the handle in a clockwise motion while pushing 

down on the handle.

NOTE: 

If the cable is not advancing, set the forward/

reverse switch to the reverse position ◄, and continue 

advancing the cable. Once the cable becomes unstuck, 

set the forward/reverse switch back to the forward 

position ►.

5. If more cable is needed, release the second half of 

the cable.

Releasing the Second Half of Cable

1.  Pull up the cable sleeve to the red cable lock indicator 

line. 

NOTE: 

The red line should be just below the handle cap.

2. Push down on the lower grip to lock the cable in 

place . 

3. Press in the cable detent ball and pull up the cable 

sleeve until the ball locks into the next detent.

4.  Pull the lower grip up to unlock the cable 

 .

 

5.  Continue feeding the cable into the drain.

2

3

4

Removing the Blockage

1.  When the clog is reached, move the tool in a back 

and forth motion until the obstruction is cleared. If 

the tool binds, release the trigger immediately. 

NOTE: 

If the cable is not advancing, please see the 

"Unbinding Auger Cables" section. 

2. Repeat until the drain is clear.

NOTE:

 The toilet auger can also be used to retrieve 

obstructions from the drain.

Unbinding Cables

1. If using the Trapsnake™ driver, set the forward/

reverse switch to the reverse position ◄. If using 

the auger handle, rotate the handle in a counter-

clockwise motion. 

2. Withdraw the tool a few inches while in reverse to 

free the cable.

3. Stop the tool.

4. After the tool has come to a complete stop, switch 

back to the forward position ►.

CAUTION

Running the tool in reverse for extended  

periods can cause damage to the cable 

and accessories.

Removing Cable from Drain

1. Set the Trapsnake™ driver forward/reverse switch 

to the forward position ►.

2. Pull the trigger slightly and pull the tool back to 

remove the cable from the drain. If using the auger 

handle, rotate the handle in a clockwise motion while 

pulling up on the handle until the cable is retracted 

from the drain.

3. If the second half of the cable was released, the 

additional cable must be returned.

SYMBOLOGY

 

  

Volts

 

 

Direct Current

 

  No-Load Revolutions per Minute (RPM)

 

C

US

  UL Listing Mark for

 

  Canada and U.S.

 

 

 

 

 

Always wear leather gloves

SPECIFICATIONS

Cat. No. .................................................... 49-16-2574

Description......................Trapsnake™ 4' Urinal Auger

Applications ....................................................... Urinal

Cable Type .............................................3/8" x 4' Bulb

Cat. No. .................................................... 49-16-2576

Description.......................Trapsnake™ 6' Toilet Auger

Applications ........................................................ Toilet

Cable Type ............................. 1/2" x 6' Retriever Bulb

Cat. No. .................................................... 14-50-2576

Description........................ M12™ Trapsnake™ Driver

Applications ...........................Toilet, Urinal, Floor Trap

Volts ...................................................................12 DC

No Load RPM ...................................................0 - 500

Battery Type ..................................................... M12™

Charger Type .................................................... M12™

ASSEMBLY

WARNING

Recharge only with the charger 

specified  for  the  battery.  For  spe

-

cific  charging  instructions,  read  the  operator’s 

manual supplied with your charger and battery.

Removing/Inserting the Battery

To 

remove

 the battery, push in the release buttons and 

pull the battery pack away from the Trapsnake™ driver.

WARNING

Always remove battery pack before 

changing or removing accessories. 

To 

insert

 the battery, slide the pack into the body of 

the Trapsnake™ driver. Make sure it latches securely 

into place.

Fuel Gauge

To determine the amount of charge left in the battery, 

pull the Trapsnake™ driver trigger. The fuel gauge 

will light up for 2-3 seconds. 

To signal the end of charge, 1 light on the fuel gauge 

will flash for 2-3 seconds.

Installing the Auger Handle/ 

Trapsnake™ Driver

Always remove the battery before inserting or remov-

ing the Trapsnake™ driver.

1. To

 install

 the auger handle or Trapsnake™ driver, 

press the auger connection into the auger socket 

until the auger collar snaps back and the auger 

connection is locked into place.

2. To 

remove

 the auger handle or Trapsnake™ driver, 

pull out the auger collar, then pull out the auger 

connection.

Returning the Second Half of Cable

1. Pull the cable sleeve up as far as it will go, and push 

down on the lower grip to lock the cable in place  . 

2. Push the detent ball in and push the cable sleeve 

down until the ball locks into the next detent. 

3. Pull the lower grip up to unlock the cable  , and 

continue returning the cable from the drain.

1

3

2

MAINTENANCE

Cable Installation

WARNING

To reduce the risk of injury, wear  

safety goggles or glasses with side 

shields. Always wear leather gloves. Cable tip may 

be sharp.

Replace cables as needed. See chart for accessory 

part numbers and compatibility.

To remove the cable:

1.  Remove the auger handle or Trapsnake™ driver from 

the auger.

2. Unclip the cable from the cable clip. 

3. Remove the two screws from the auger handle cap. 

4. Pull the cable sleeve up to the red cable lock indi-

cator line. Push down on the lower grip to lock the  

cable  . 

5. Press the cable detent ball in and pull the cable 

sleeve up until the ball locks into the next detent. 

6. Pull the lower grip up to unlock the cable 

.

 

  Press the cable detent ball in once more and pull the 

cable out from the bottom of the auger.

7. When cleaning or maintaining the cable, follow the 

cleaning instructions under "Maintenance".

To install the cable:

1.  Remove the auger handle or Trapsnake™ driver from 

the auger.

2. Remove the two screws from the auger handle cap. 

3. Pull the lower grip up to unlock the cable 

.

 

4. Feed the cable into the auger through the bottom of 

the tool until the cable detent section reaches through 

the upper grip.

5. Push down on the lower grip to lock the cable  . 

Line up the cable detent ball with the cable sleeve 

detent. Press the cable detent ball in and push the 

cable sleeve down until the ball locks into the first 

detent. 

6. Press the cable detent ball in once more and push 

the cable sleeve down until the ball locks into the 

next detent.

Summary of Contents for TRAPSNAKE 14-50-2576

Page 1: ...E PORCELANA OPERATOR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de réduire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el usuario debe leer y entender el manual ...

Page 2: ...us and must be repaired Disconnect the plug from the power source and or remove the battery pack if detachable from the power tool before making any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accidentally Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool...

Page 3: ...g Cable from Drain 1 Set the Trapsnake driver forward reverse switch to the forward position 2 Pull the trigger slightly and pull the tool back to remove the cable from the drain If using the auger handle rotate the handle in a clockwise motion while pulling up on the handle until the cable is retracted from the drain 3 If the second half of the cable was released the additional cable must be retu...

Page 4: ...LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTYAS DESCRIBED ABOVE SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE This warranty applies to product sold in the U S A and Canada only Please consult the Servi...

Page 5: ...as laisser le couteau cesser de tourner pen dant que le câble tourne Ceci peut forcer le câble et en causer la torsion la déformation ou la rupture entraînant des blessures graves Utiliser des gants en latex ou en caoutchouc à l intérieur des gants recommandés par le fabricant des lunettes des masques protecteurs des vête ments de protection et un respirateur lorsque la présence de produits chimiq...

Page 6: ...lisation de la poignée de la tarière faire tourner la poignée dans le sens des aiguilles d une montre tout en poussant la poignée vers le bas REMARQUE Si le câble est bloqué régler l inverseur du sens de rotation en position marche arrière et continuer à faire avancer le câble Une fois que le câble est libéré remettre l inverseur du sens de rotation en position marche avant 5 Si une longueur suppl...

Page 7: ...RS EXCLUSIFS DE RÉPARATION ETDE REMPLACEMENT DÉCRITS DANS LES PRÉSENTES EST UNE CON DITION DU CONTRAT D ACHAT DE TOUT PRODUIT MILWAUKEE SI VOUS N ACCEPTEZ PAS CETTE CONDITION VOUS NE DEVEZ PAS ACHETER LE PRODUIT ENAUCUN CAS MILWAUKEE NE SAURAIT ÊTRE RESPONSABLE DE TOUT DOMMAGEACCESSOIRE SPÉCIAL OU INDIRECT DE DOMMAGES INTÉRÊTS PUNITIFS OU DE TOUTE DÉPENSE D HONORAIRES D AVOCATS DE FRAIS DE PERTE O...

Page 8: ...eden mostrar un comportamiento impredec ible causando incendios explosión o riesgo de lesión No exponga una batería o herramienta al fuego o a temperaturaexcesiva Laexposiciónafuegootemper aturaamásde130 C 265 F puedecausarexplosiones Siga todas las instrucciones de carga y no car gue la batería o la herramienta fuera del rango de temperatura especificado en las instrucciones La carga incorrecta o...

Page 9: ... gatillo mayor será la velocidad 3 Para detener la herramienta suelte el gatillo APLICACIONES ADVERTENCIA Para reducir el riesgo de lesio nes extraiga siempre la bat ería antes de acoplar o desacoplar accesorios Utilice únicamente accesorios específicamente recomendados para esta herramienta El uso de accesorios no recomendados podría resultar peli groso Para reducir el riesgo de lesiones use siem...

Page 10: ... aplica a daños que MILWAUKEE determine que son ocasionados por reparaciones o intentos de reparaciones realizados por una persona que no sea personal autorizado de MILWAUKEE uso indebido alteraciones maltrato desgaste normal falta de mantenimiento o accidentes Desgaste normal Muchas herramientas eléctricas necesitan reem plazos periódicos de partes y servicio para lograr el mejor rendimiento Esta...

Page 11: ...58142576d1 961012080 01 A 12 16 Printed in China MILWAUKEE TOOL 13135 West Lisbon Road Brookfield WI 53005 USA ...