4
SYMBOLOGY
Volts
Direct Current
No-Load Revolutions per Minute (RPM)
Read operator's manual.
Always wear leather gloves over
latex/rubber gloves.
Wear eye protection.
Do not allow battery to contact
corrosive or conductive fluid.
o
Forward/OFF/Reverse
C
US
UL Listing for Canada and U.S.
ASSEMBLY
WARNING
Recharge only with the charger
specified for the battery. For spe
-
cific charging instructions, read the operator’s
manual supplied with your charger and battery.
Removing/Inserting the Battery
To
remove
the battery, unlatch the battery door, push
in the release buttons and pull the battery pack away
from the tool. Close and relatch the battery door.
WARNING
Always remove battery pack before
changing or removing accesso-
ries.
To
insert
the battery, unlatch the battery door and slide
the pack into the body of the tool. Make sure it latches
securely into place. Close and relatch the battery door.
WARNING
Only use accessories specifically
recommended for this tool. Others
may be hazardous.
Selecting the Proper Cable
Different size and types of cables are available for
different applications. Remove the protective tip
cover from new cables before use.
Cat. No.
Description
48-53-2680
5/8" X 7-1/2' All-Purpose Open Wind
Sectional Cable
48-53-2852
7/8" x 15' All-Purpose Open Wind
Sectional Cable
CAUTION
To prevent damage to the cable and
attachments, do not use in larger
diameter pipes.
Cable Attachment Installation
To install the attachment:
Snap the attachment coupler into the cable coupler.
Test the cable before inserting into the drain to make
sure the attachment does not fall off during use.
To remove the attachment:
Insert the pin key into the coupling hole and pull at-
tachment off of cable.
SPECIFICATIONS
Cat. No. ..................................................... 2818-20
Volts
..............................................................
18 DC
Battery Type
.................................................
M18™
Charger Type
................................................
M18™
No Load RPM
....................................................
650
Cable Sizes
............................................5/8" & 7/8"
Recommended Pipe Diameter
..................1-1/4"-6"
Recommended Ambient
Operating Temperature
....................
0°F to 125°F
FUNCTIONAL DESCRIPTION
1.
Lever arm
2.
Lever arm hook
3. Lever latch/cable size selector
4.
Front collar
5.
Carry strap connection point
6.
Pin key holder
7.
Rear guide hose connection
8.
Cable hook
9.
Drainage port
10.
Battery compartment
11. Forward/Off/Reverse
12.
ONE-KEY™ indicator
13.
Guide hose (not shown)
14.
Carry strap (not shown)
2
12
8
11
10
7
3
2
1
6
9
5
5
4