background image

4

SYMBOLOGY

 

  

Volts

 

 

Direct Current

 

  No-Load Revolutions per Minute (RPM)

 

 

Read operator's manual.

    

 

  Always wear leather gloves over   

 

 

 

latex/rubber gloves. 

 

 

Wear eye protection.

 

 

  Do not allow battery to contact  

 

 

  corrosive or conductive fluid.

 

o

 

Forward/OFF/Reverse

 

C

US

  UL Listing for Canada and U.S.

 

ASSEMBLY

WARNING

Recharge only with the charger 

specified for the battery. For spe

-

cific charging instructions, read the operator’s 

manual supplied with your charger and battery.

Removing/Inserting the Battery

To 

remove

 the battery, unlatch the battery door, push 

in the release buttons and pull the battery pack away 

from the tool. Close and relatch the battery door.

WARNING

Always remove battery pack before 

changing or removing accesso-

ries. 

To 

insert

 the battery, unlatch the battery door and slide 

the pack into the body of the tool. Make sure it latches 

securely into place. Close and relatch the battery door.

WARNING

Only use accessories specifically 

recommended for this tool. Others 

may be hazardous.

Selecting the Proper Cable

Different size and types of cables are available for 

different  applications.  Remove  the  protective  tip 

cover from new cables before use.

Cat. No.

Description

48-53-2680

5/8" X 7-1/2' All-Purpose Open Wind 

Sectional Cable

48-53-2852

7/8" x 15' All-Purpose Open Wind 

Sectional Cable

 

CAUTION

To prevent damage to the cable and 

attachments, do not use in larger 

diameter pipes.

Cable Attachment Installation

To install the attachment:

Snap the attachment coupler into the cable coupler. 

 

Test the cable before inserting into the drain to make 

sure the attachment does not fall off during use.

To remove the attachment:

Insert the pin key into the coupling hole and pull at-

tachment off of cable.

SPECIFICATIONS

Cat. No. ..................................................... 2818-20 

Volts

..............................................................

18 DC

Battery Type

 .................................................

M18™

Charger Type

................................................

M18™

No Load RPM

 ....................................................

650

Cable Sizes

 ............................................5/8" & 7/8"

Recommended Pipe Diameter

 ..................1-1/4"-6"

Recommended Ambient 

   Operating Temperature

 ....................

0°F to 125°F

FUNCTIONAL DESCRIPTION

1. 

Lever arm

2. 

Lever arm hook

3. Lever latch/cable size selector

4. 

Front collar

5. 

Carry strap connection point

6. 

Pin key holder

7. 

Rear guide hose connection

8. 

Cable hook

9. 

Drainage port

10. 

Battery compartment

11. Forward/Off/Reverse

12. 

ONE-KEY™ indicator

13. 

Guide hose (not shown)

14. 

Carry strap (not shown)

2

12

8

11

10

7

3

2

1

6

9

5

5

4

Summary of Contents for M18 FUEL 2818-20

Page 1: ...er must read and understand operator s manual AVERTISSEMENT Afin de r duire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el...

Page 2: ...ry Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations Dress properly Do not wear loose clothing or jewelry Keep your h...

Page 3: ...which may result in entangle ment and personal injury Keep a gloved hand on the cable whenever the tool is running This provides better control of the cable and helps prevent twisting kinking or break...

Page 4: ...ze and types of cables are available for different applications Remove the protective tip cover from new cables before use Cat No Description 48 53 2680 5 8 X 7 1 2 All Purpose Open Wind Sectional Cab...

Page 5: ...the battery pack before performing mainte nance transporting the tool changing accessories storing the tool and any time the tool is not in use Inserting Cable Into Drain 1 Place the tool at a distan...

Page 6: ...ding on use return the tool battery pack and charger to a MILWAUKEE service facility for inspection If the tool does not start or operate at full power with a fully charged battery pack clean the cont...

Page 7: ...Bulb fails the part will be replaced free of charge Warranty Registration is not necessary to obtain the applicable war ranty on a MILWAUKEE power tool product The manufacturing date of the product wi...

Page 8: ...imites pr vues Ne pas utiliser l outil lectrique si le commutateur nepermetpasdelemettreenmarcheoudel arr ter Tout outil lectrique qui ne peut pas tre contr l par son commutateur est dangereux et doit...

Page 9: ...toute la fois que l outil tourne Ceci vous permettra de mieux contr ler le c ble au m me temps qu il vite la torsion le pliage et le cassage du c ble ce qui pourra causer des blessures physiques grav...

Page 10: ...et 22 2 mm 7 8 Diam tre de tuyau recommand 31 8 mm 1 1 4 152 4 mm 6 Temp rature ambiante de fonctionnement recommand e 18 C 50 C 0 F 125 F PICTOGRAPHIE Volts Courant direct Tours minute vide RPM Lire...

Page 11: ...ce de raccord et tirer les c bles pour les s parer 1 2 Utilisation de la poign e t lescopique Pour utiliser la poign e t lescopique appuyer et tenir enfonc le bouton de d verrouillage qui se trouve pr...

Page 12: ...n porteur pourra causer de blessures de coups ou d crassage 5 Faire tourner le commutateur Marche avant arr t marche arri re vers la position avant afin de faire tourner le c ble 6 Attacher plus de c...

Page 13: ...flammables ou combustibles aupr s des outils Nettoyagedec bles detubesetdelamachine Le c ble et le tube doivent tre soigneusement rinc s l eau apr s chaque utilisation afin d viter les effets nuisible...

Page 14: ...QUI VARIENT D UN TAT UN AUTRE Cette garantie s applique aux produits vendus aux tats Unis et au Canada uniquement Veuillez consulter la rubrique Centre SAV Milwaukee dans la sec tion Pi ces et Servic...

Page 15: ...cuerdo con estas instrucciones tomando en cuenta las condiciones de trabajo y el trabajo a realizar El uso de la herramienta el ctrica para operaciones diferentes a las previstas podr a generar una si...

Page 16: ...r de drenaje a una distancia menor a 61 cm dos pies de la abertura del drenaje Si el limpiador de drenaje no puede colocarse en una distancia de 61 cm dos pies de la abertura del drenaje esta necesita...

Page 17: ...omendados podr a resultar peligroso Seleccionar el cable adecuado Hay varios tipos y tama os de cables disponibles para distintas aplicaciones Retire la cubierta de punta protectora de los cables nuev...

Page 18: ...a hacia el extremo frente al brazo de la palanca Verifique la direcci n de rotaci n antes de usar 3 Para bloquear el interruptor g relo hacia su posici n central O El cable no girar mientras el interr...

Page 19: ...EY ADVERTENCIA Riesgo de quem adura qu mica Este dispositivo contiene una bater a de bot n tipo moneda de litio Una bater a nueva o usada puede causar quemaduras internas graves y causar la muerte tan...

Page 20: ...ones anteriores Si durante el uso normal el LED o Bulbo de LED falla la parte ser reemplazada sin cargo No se requiere el registro de la garant a para obtener la garant a cor respondiente a un product...

Reviews: