5

Status Indicator

LED

Indicates

Action

Flashing 

White

Rotation 

complete

Insert into tubing and release 

the trigger

Solid Green Expansion 

in progress

Tool will continue to expand to 

maximum diameter

Flashing 

Green

Expansion 

complete

Start process for next 

expansion

Flashing Red Expansion 

error

Correct the error and restart 

the expansion process

Flashing Red 

and Green

Service 

required

Contact a MILWAUKEE 

service facility for ALL repairs.

Cold-weather Use

Colder weather (<40°F/4°C) requires a longer con

-

traction time and fewer expansions. 

Troubleshooting ProPEX

®

 Connections

If fittings will not seal, check for the following:

• 

Is the expander head screwed on tightly? 

Tighten 

the head securely. Ensure the head is tight against 

the tool.

• 

Are the expander head segments bent or mis-

aligned? 

Replace expander head.

 Are the expander head segments failing to contract 

between expansions?

 Clean the head and lubricate 

the cone. Ensure cogs are engaged.

Cogs

Is the expander cone over or under lubricated? 

Clean and lubricate.

 Is the fitting damaged?

 Replace fitting.

 Is the expander cone bent or damaged?

 Return to 

a MILWAUKEE service facility for repair.

• 

Was the expander head held in the expanded posi-

tion before tubing was removed?

 Cut 3"-5" (3" for 2" 

PEX and 5" for 2.5" and 3" PEX) off the end of the 

tubing and restart the procedure with a new ProPEX

®

 

Ring.

• 

Was the tubing rotated slightly after each expan-

sion?

 Cut 3"-5" (3" for 2" PEX and 5" for 2.5" and 

3" PEX) off the end of the tubing and restart the 

procedure with a new ProPEX

®

 Ring.

• 

Are the tubing and ProPEX

®

 Ring clean and dry? 

Wipe dry.

• 

Is grease getting into the tubing from the expander 

head?

 Wipe grease from tubing. Clean the expander 

head, ensuring excessive amounts of grease are not  

present on the head.

If ProPEX

®

 Ring slides during expansion:

• 

Are the tubing and ProPEX

®

 Ring clean and dry? 

Wipe clean.

• 

Are your hands clean and dry?

 Wipe dry — oils from 

your hands can lubricate the tubing and ProPEX

®

 

Ring.

• 

Are you holding the ring in place?

 Place your thumb 

against the ring and hold in place during first couple 

of expansions.

If expander head does not expand when trigger is 

pulled:

• 

Verify that the expander head is fully retracted. 

• 

Set tool on a work surface with the cone pointing up. 

Pull the trigger and hold until the green light indicates 

that the press cycle has started. Release the trigger 

and then press and hold the manual retract button un-

til the motor stops (up to 1 minute). Repeat if expand

-

er head still does not expand when trigger is pulled.

If the head does not fully retract at the end of an 

expansion:

• 

Press the manual release button to fully retract the 

expander cone

• 

Remove the expander head from the tool and rein-

stall, verifying proper installation.

MAINTENANCE

WARNING

To reduce the risk of injury, always 

unplug the charger and remove the 

battery  pack  from  the  charger  or  tool  before 

performing any maintenance. Never disassemble 

the  tool,  battery  pack  or  charger.  Contact  a 

MILWAUKEE service facility for ALL repairs.

Maintaining Tool 

Keep your tool, battery pack and charger in good 

repair by adopting a regular maintenance program.

Each month:

• Remove the expander head and

Lubrication 

areas

soak in degreasing agent to 

remove grease from between 

expander segments.  Re-lubri

-

cate head (expander head 

collar groove, expander cone 

mating surface).

• Wipe expander cone and rotate 

collar with clean, dry, lint-free 

cloth.  Re-lubricate when com

-

plete. 

After six months to one year, 

depending on use, return the tool, battery pack and 

charger to A MILWAUKEE service facility for:

• Lubrication

• Mechanical inspection and cleaning (gears, spin-

dles, bearings, housing, etc.)

• Electrical inspection (battery pack, charger, motor)

• Testing to assure proper mechanical and electrical 

operation

If the tool does not start or operate at full power with 

a fully charged battery pack, clean the contacts on 

the battery pack. If the tool still does not work prop

-

erly, return the tool, charger and battery pack, to a 

MILWAUKEE service facility for repairs.

ONE-KEY™

Refer to the ONE-KEY App for information regarding 

necessary servicing, such as internal battery life and 

crimp count. 

WARNING

Chemical Burn Hazard.

 

This device contains a 

lithium button/coin cell battery. A new 

or used battery can cause severe in

-

ternal burns and lead to death in as 

little as 2 hours if swallowed or enters the body. 

Always secure the battery cover. If it does not 

close securely, stop using the device, remove the 

batteries, and keep it away from children. If you 

think  batteries  may  have  been  swallowed  or 

entered the body, seek immediate medical atten

-

tion.

Summary of Contents for M18 FORCELOGIC 2633-20

Page 1: ...GICTM M18TM DE 50 8 mm 76 2 mm 2 3 OPERATOR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin...

Page 2: ...injury Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations Dress properly Do not wear loose clothing or jewelry Keep y...

Page 3: ...lling and other construction activities contains chemicals known to cause cancer birth defects or other reproductive harm Some examples of these chemicals are lead from lead based paint crystalline si...

Page 4: ...g shoul der If more than 1 16 gap between tubing and shoulder cut 3 5 3 for 2 PEX and 5 for 2 5 and 3 PEX off the end of the tubing and restart the procedure with a new ProPEX Ring Attaching the Side...

Page 5: ...ool on a work surface with the cone pointing up Pull the trigger and hold until the green light indicates that the press cycle has started Release the trigger and then press and hold the manual retrac...

Page 6: ...rade Titan Industrial Work Carts is one 1 year from the date of purchase The warranty period for the Drain Cleaning Cables is two 2 years from the date of purchase The warranty period for the M18 Comp...

Page 7: ...t individuelle S CURIT INDIVIDUELLE Rester attentif pr ter attention au travail et faire preuve de bon sens lors de l utilisation de tout outil lectrique Ne pas utiliser cet appareil en cas de fatigue...

Page 8: ...une explosion Suivre toutes les instructions de charge et ne pas charger le bloc piles ou l outil en dehors de la plage de temp rature sp cifi e Une charge incorrecte ou des temp ratures en dehors de...

Page 9: ...Pour installer une t te d largissement 1 Retirer le bloc piles 2 Placer l outil avec la t te orient e vers le haut 3 V rifier que le c ne largisseur est compl tement rentr 4 Visser la t te sur l outi...

Page 10: ...e lorsque les segments sont con tract s 9 Faire glisser le tubage sur le raccord jusqu ce qu il soit galit avec l paulement du raccord S il n est pas possible de glisser le tubage sur le raccord le re...

Page 11: ...brifier lorsque vous avez termin Apr s une p riode de six mois un an selon l utilisation renvoyez l outil la batterie et le chargeur un centre de service MILWAUKEE accr dit pour les services suivants...

Page 12: ...E TOUT PRODUIT MILWAUKEE SI VOUS N ACCEPTEZ PAS CETTE CONDITION VOUS NE DEVEZ PAS ACHETER LE PRODUIT EN AUCUN CAS MILWAUKEE NE SAURAIT TRE RESPONSABLE DE TOUT DOMMAGE ACCESSOIRE SP CIAL OU INDIRECT DE...

Page 13: ...Trasladar her ramientas con el dedo en el interruptor o energizar herramientas el ctricas que tienen el interruptor encendido propicia accidentes Retire cualquier llave de ajuste antes de entender la...

Page 14: ...nicamente piezas de reemplazo id nticas Esto asegurar que la seguri dad de la herramienta el ctrica se mantenga Nunca d servicio a bater as da adas nicamente el fabricante o proveedores de servicio a...

Page 15: ...oreado de segmentos a Aseg rese de que los seg mentos de la cabeza no se floreen b Gire los tres segmentos ex pansores hacia la derecha Girar n libremente No deben girar hacia la izquierda c La cabeza...

Page 16: ...nalizada Inicie el proceso de la siguiente expansi n Roja intermitente Error de expansi n Corrija el error y reinicie el proceso de expansi n Roja y verde intermitentes Se requiere servicio Comun ques...

Page 17: ...un centro de servicio MILWAUKEE para que sea reparada ONE KEY Consulte la aplicaci n ONE KEY para obtener infor maci n referente al servicio necesario como la vida de la bater a interna y el recuento...

Page 18: ...USIVOS DE REPA RACI N Y REEMPLAZO AQU DESCRITOS ES UNA CONDICI N DEL CONTRATO PARA LA COMPRA DE TODO PRODUCTO DE MILWAUKEE SI USTED NO ACEPTA ESTA CONDICI N NO DEBE COMPRAR EL PRODUCTO MILWAUKEE NO SE...

Page 19: ...19...

Page 20: ...58140076d2 961012519 01 A 09 17 Printed in China MILWAUKEE TOOL 13135 West Lisbon Road Brookfield WI 53005 USA...

Reviews: