4
OPERATION
WARNING
To reduce the risk of injury, always
wear proper eye protection marked
to comply with ANSI Z87.1.
Always remove battery pack before changing
or removing accessories. Only use accessories
specifically recommended for this tool. Others
may be hazardous.
Pressing
•
Before beginning a press, inspect the jaw assembly
for cracks or other damage. Do not use a damaged
jaw assembly. Return damaged jaw assembly
to a
MILWAUKEE service facility.
•
The tool will turn off automatically after 40 seconds
of no use.
•
Inspect and discard workpieces with cracks or wear
before use. Materials may crack or shatter.
1. Turn the tool
ON
by quickly pressing and releasing
the start button.
2. Open the jaws and
place around the
fitting.
3. Hold tool securely.
Press and hold the
start button. The
green LED will go
out.
4. The automatic
press cycle be-
gins. Release the
start button and
continue to hold
the tool securely.
5. When the press
cycle is complete
the tool will switch
off and the green
LED will light.
6. To cancel the auto
-
matic press cycle,
press and hold the
release button. Hold tool securely until jaws open
and the tool turns off.
7. If the tool is in use for 30 minutes continuously
(e.g., on a manufacturing fixture), allow the tool to
cool down for at least 15 minutes before continu-
ing. Under normal use (e.g., plumbing/mechanical)
press freely and pay attention to the LED indicators
(see "Troubleshooting").
8. If the red LED lights, press the start button. If the
tool does not run, return the tool to a MILWAUKEE
service facility for repairs.
9. If the red and green LEDs blink alternately, the
tool must be serviced by a MILWAUKEE service
facility.
ASSEMBLY
WARNING
Recharge only with the charger
specified for the battery. For spe
-
cific charging instructions, read the operator’s
manual supplied with your charger and battery.
Removing/Inserting the Battery
To
remove
the battery, push in the release buttons
and pull the battery pack away from the tool.
WARNING
Always remove battery pack before
changing or removing accessories.
To
insert
the battery, slide the pack into the body
of the tool. Make sure it latches securely into place.
WARNING
Only use accessories specifically
recommended for this tool. Others
may be hazardous.
Use tool only with MILWAUKEE or MILWAUKEE
approved press jaws, press fittings, and pipe for
which they are designed. Other uses may cause
injury or damage to the tool, accessories, and
pipes. Leaking may result.
Inserting/Removing the Press jaw
1. Pull out the retaining pin (1).
2. Insert the press jaw (2).
3. Push in the retaining pin (3).
2
1
3
CAUTION
To avoid damage to the tool, do not
operate the tool without the retaining
pin fully inserted. Damage to the cylinder may occur.
ONE-KEY™
To learn more about the ONE-KEY™ functionality for
this tool, please refer to the quick reference included with
this product or go to milwaukeetool.com/One-Key. To
download the ONE-KEY™ app, visit the App Store or
Google Play from your smart device.
ONE-KEY™ Indicator
Solid Blue
Wireless mode is active and ready
to be configured via the ONE-KEY™
app.
Blinking Blue Tool is actively communicating with
the ONE-KEY™ app.
Blinking Red
Tool is in security lockout and can
be unlocked by the owner via the
ONE-KEY™ app.