Taille de câble

(code 

uniquement)

Code 

couleur

No de cat.

Empreinte 

de matrice

Cosses : Nombre total de sertissages    

Épissures : Nombre de sertissages par côté

Anderson

Blackburn

®

  Burndy  ILSCO Panduit Penn-Union

T&B

#8 AWG

ROUGE

49-12-U008C

8

1

1

1

1

1

1

#6 AWG

BLEU

49-12-U006C

6

#4 AWG

GRIS

49-12-U004C

4

1

#2 AWG

MARRON

49-12-U002C

2

#1 AWG 

+

VERT

49-12-U001C

1

1/0 AWG

ROSE

49-12-U01AC

1/0

2/0 AWG

NOIR

49-12-U02AC

2/0

3/0 AWG

ORANGE

49-12-U03AC

3/0

4/0 AWG

VIOLET

49-12-U04AC

4/0

250 MCM

JAUNE

49-12-U250C

250

300 MCM

BLANC

49-12-U300C

300

2

2

2

2

2

2

2

350 MCM

ROUGE

49-12-U350C

350

Cosses: 2

Épissures: 

N/A

400 MCM

BLEU

49-12-U400C

400

2

500 MCM

MARRON

49-12-U500C

500

600 MCM

VERT

49-12-U600C

600

750 MCM

NOIR

49-12-U750C

750

750 MCM

NOIR

49-15-P750C 

*

750P

3

3

3

3

3

3

3

800 MCM

ORANGE

49-15-P800C 

*

800P

1000 MCM

BLANC

49-15-P000C 

*

1000P

Cosses et épissures courtes et longues en cuivre

Anderson

Blackburn

®

 

Burndy 

ILSCO

Panduit

Penn-Union

T&B

Modèles d'épissures 

numéros

VHS,

VHSS

CSP, CU

YS, YS-L,

YS-T

CT, CTL

SCH, SCL,

SCS, SCSS

BBCU,

BCU

54504-54528,

54804-54828

Modèles de cosses 

numéros

VHCL,

VHCS

CTL,

CTL-2,

CTL-L,

LCN

YA, YAZ, YA-L, YA-2L, 

YA-2LN, YA-L-NT, 

YA-L-2NT, YA-L-TC, 

YA-L-2TC, YA-2N, 

YA-TC, YA-2TC

CLN, CLND, CLNS, 

CLW, CLWD, CRA,

CRB, CRA-L, CRB-L, 

CRA-2L, CRB-2L, 

CSW, CSWS

LCA, LCAS,

LCB, LCC,

LCD

BBLU,

BLU

54104-54128,

54204-54228,

54930BE-

54928BE,

54850BE-54882BE

Les connexions réalisées avec l’outil (2879-20), l'adaptateur (49-15-PUAD) et la combinaison matrice-

connecteur dont vous pouvez trouver les références dans les graphiques ci-dessous produisent des 

sertissages homologués UL selon la norme UL 486A-B. *Les connexions faites avec ces numéros de 

catalogue de matrice créent des sertissages classés UL sans l'utilisation de l'adaptateur.

Taille de câble

(code 

uniquement)

Code 

couleur

No de cat.

Empreinte 

de matrice

Cosses : Nombre total de sertissages    

Épissures : Nombre de sertissages par côté

Anderson

Blackburn

®

  Burndy 

ILSCO

Panduit Penn-Union T&B

#8 AWG

BLEU

49-12-U008

8

Cosses: N/A

Épissures: 1

Cosses: 1

Épissures: 

N/A

1

1

Cosses: 1

Épissures: 

N/A

1

#6 AWG

GRIS

49-12-U006

6

#4 AWG

VERT

49-12-U004

4

#2 AWG

ROSE

49-12-U002

2

1

1

1

#1 AWG

DORÉ

49-12-U001

1

2

2

2

2

2

2

2

1/0 AWG

BRUN CLAIR 

49-12-U01A

1/0

2/0 AWG

OLIVE

49-12-U02A

2/0

3/0 AWG

RUBIS

49-12-U03A

3/0

4/0 AWG

BLANC

49-12-U04A

4/0

250 MCM

ROUGE

49-12-U250

250

300 MCM

BLEU

49-12-U300

300

350 MCM

MARRON

49-12-U350

350

400 MCM

VERT

49-12-U400

400

3

3

3

3

3

3

3

500 MCM

ROSE

49-12-U500

500

600 MCM

BLACK

49-12-U600

600

750 MCM

NOIR

49-12-U750

750

750 MCM

NOIR

49-15-P750 

*

750P

4

4

4

4

800 MCM

GRIS

49-15-P800 

*

800P

1000 MCM

MARRON

49-15-P000 

*

1000P

Cosses et épissures à double homologation

Anderson

Blackburn

®

  Burndy 

ILSCO

Panduit

Penn-Union

T&B

Modèles d'épissures 

numéros

VACS

ASP

YS-A

AS,

ASN

SA

BCUA

60501-60584

Modèles de cosses 

numéros

VACL

ATL

YA-A,

YA-ATN

ACL, ACN, ALND, ALNS, 2ACL, 

2ACN, ALNN

LAA, 

LAB

BLUA

60101-60184 et

60230-60284

Nombre de frisures est un minimum. Des sertissures supplémentaires n'affecteraient pas négativement l'intégrité de la connexion du moment 

qu'elles sont placées uniformément entre la zone de sertissage prévue du connecteur, généralement délimitée par des bandes de couleur ou 

des molettes. Pour la liste d’approbation la plus récente, veuillez visiter milwaukeetool.com. Pour une assistance technique, veuillez contacter 

le service à la clientèle de Milwaukee en composant le 1-800-729-3878.

Tableau A

 - États-Unis

+ Concentrique ou compressé uniquement 

Summary of Contents for M18 FORCE LOGIC 2879-20

Page 1: ...and understand operator s manual AVERTISSEMENT Afin de r duire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo de lesiones el usuario debe...

Page 2: ...sonal injury Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations Dress properly Do not wear loose clothing or jewelry K...

Page 3: ...iece Chemical Burn Hazard Keep coin cell battery away from children Always use common sense and be cautious when using tools It is not possible to anticipate every situation that could result in a dan...

Page 4: ...B LCC LCD BBLU BLU 54104 54128 54204 54228 54930BE 54928BE 54850BE 54882BE Connections made with this tool 2879 20 Adapter 49 15 PUAD and combination of die and con nector part numbers in the charts b...

Page 5: ...assified crimps according to the UL 486A B standard The connections made with these die cat no s create UL classified crimps without the use of the adapter Dual Rated Lugs Splices Anderson Blackburn B...

Page 6: ...de of the jaws Dies will snap into place after pins are released Tug on dies to ensure they are secure 4 When using U dies first install the adapter then snap the U dies into each side of the jaws Tug...

Page 7: ...low inside them Cleaning Clean dust and debris from vents Keep handles clean dry and free of oil or grease Use only mild soap and a damp cloth to clean since certain clean ing agents and solvents are...

Page 8: ...anty period for Job Site Radios M12 Power Port M18 Power Source Jobsite Fan and Trade Titan Industrial Work Carts is one 1 year from the date of purchase The warranty period for the M18 FUEL 1 D Handl...

Page 9: ...assurer que la g chette est en position d arr t avant de brancher l outil une source de courant d ins rer la batterie de le ramasser ou de le transporter Le fait de transporter un outil lectrique en...

Page 10: ...oires matrices et connecteurs doivent tre de COMBI NAISON DE TAILLE APPROPRI E Des combinai sons incompatibles peuvent r sulter en un sertissage d fectueux Une occurrence de choc lectrique un incendie...

Page 11: ...faites avec ces num ros de catalogue de matrice cr ent des sertissages class s UL sans l utilisation de l adaptateur Taille de c ble code uniquement Code couleur No de cat Empreinte de matrice Cosses...

Page 12: ...86A B Les connexions faites avec ces num ros de catalogue de matrice cr ent des sertissages class s UL sans l utilisation de l adaptateur Taille de c ble code uniquement Code couleur No de cat Emprein...

Page 13: ...s doivent tre de combinaison de taille appropri e Des combinaisons incompatibles peuvent r sult er en un sertissage d fectueux Une occurrence de choc lectrique un incendie une explosion et des dommage...

Page 14: ...te compl tement 6 Pourenleverlesmatricesen U cellesqu utilisent l adaptateur appuyer sur les boutons de d verrouil lage de matrice qui se trouvent dans l adaptateur pour enlever les matrices en les gl...

Page 15: ...l essence la t r benthine les dilu ants laque ou peinture les solvants chlor s l ammoniaque et les d tergents d usage domestique qui en contiennent pourraient d t riorer le plastique et l isolation de...

Page 16: ...E DE CES GARANTIES IMPLICITES EST LIMIT E LA P RIODE APPLICABLE DE LA GARANTIE EXPRESSE TELLE QUE CELA EST D CRIT PR C DEMMENT CERTAINES PROVINCES NE PERMETTANT PAS DE LIMITATION DE DUR E DES GARANTIE...

Page 17: ...herramienta el ctrica sea reparada antes de que se utilice Muchos accidentes son ocasiona dos por herramientas el ctricas con mantenimiento deficiente Mantenga las herramientas de corte afiladas y lim...

Page 18: ...como causantes de c ncer defectos cong nitos u otros da os reproduc tivos Algunos ejemplos de estos qu micos son plomo de pintura basada en plomo di xido de silicio de los ladrillos y el cemento y ot...

Page 19: ...L 486A B Las conexiones realizadas con estos n meros de cat logo de troqueles crean crimpados clasificados UL sin el uso del adaptador Orejetas y empalmes de clasificaci n dual Anderson Blackburn Burn...

Page 20: ...cuerdo con el est ndar UL 486A B Las conexiones realizadas con estos n meros de cat logo de troqueles crean crimpados clasificados UL sin el uso del adaptador Orejetas y empalmes de clasificaci n dual...

Page 21: ...D Cambio de los Troqueles Inspeccione los troqueles y los conectores antes de usarlos Utilice nicamente troqueles y conectores que correspondan correctamente a las mordazas crimpadoras Refi rase a las...

Page 22: ...aci n de mordaza 5 Coloque las mordazas alrededor de la pieza y cierre la mordaza oscilante Presione el pasador de bloqueo 6 Los pliegues deben colocarse de manera uniforme en el barril del conector 7...

Page 23: ...re la bater a tipo moneda anterior mant ngala fuera del alcance de los ni os y desh gase de ella de la manera correcta 4 Inserte la nueva bater a tipo moneda 3V CR2032 con el lado positivo hacia arrib...

Page 24: ...cesario realizar el registro de la garant a para recibir la garant a correspondiente a un producto de herramienta el ctrica de MILWAUKEE La fecha de fabricaci n del producto servir para deter minar la...

Reviews: