background image

4

5

TERMINOLOGY

Magazine 

Capacity

120 nails

Operating 

Pressure

min. 70 PSI

max. 120 PSI

Cat. 

No.

7120-21

Specifi cations

Symbology

Air 

Consumption

.08 ft

3

/cycle at 

100 psi

Air 

Inlet

3/8  in. 

NPT

Read the Operator's Manual

Wear Eye Protection

Keep hands away

Fastener 

Length

min. 0.75"

max. 1.75"

Collation 

Angle

15°

Fastener Size 

(Diameter)

.120

Actuate

To cause movement of the tool component(s) 
intended to drive a fastener.

Actuation System

The use of a trigger, workpiece contact 
and/or other operating control, separately 
or in some combination or sequence, to 
actuate the tool.

  •  Single sequential actuation

 

An actuation system that requires the 
workpiece contact and then the trigger 
to be activated in a specifi c  sequence 
to drive a fastener.  Additional actuation 
can occur when the trigger is released 
and reactivated.

  •  Contact actuation

 

An actuation system that requires the 
workpiece contact and the trigger to be 
activated in any sequence to drive a 
fastener.  Additional actuation can occur 
when either the workpiece contact or the 
trigger is released and reactivated.

  •  Selective actuation

 

An actuation system that allows selec-
tion of actuation systems: single se-
quential actuation or contact actuation. 

Fastener

A staple, pin, brad, nail, or other fastening 
device which is designed and manufactured 
for use in the tools.

Jam

An obstruction in the feed or drive areas of 
the tool.

Workpiece Contact

An operating control element on the tool 
intended to be activated by the workpiece 
to be fastened.

SPECIFIC SAFETY INSTRUCTIONS

8. 

Do not remove, tamper with, or 
otherwise cause the tool operating 
controls to become inoperable. 

This 

will cause unexpected actuation, result-
ing in serious injury.

9. 

Do not operate a tool if any portion of 
the tool operating controls is inoper-
able, 

disconnected, altered, or not work-

ing properly. This will cause unexpected 
actuation, resulting in serious injury.

10. 

Always keep hands and body away 
from discharge area of the tool

. Never 

attempt to clear a jammed workpiece 
contact by grasping the discharge area 
of the tool.  Fasteners discharged from 
tool can cause serious injury if they 
contact hands or body. 

11. 

Do not drive fasteners close to the 
edge of the workpiece

. Fasteners can 

slip off corners and edges or penetrate 
through thin material, making them 
projectiles capable of causing serious 
injury.

12. 

Use the tool only for the intended 
purpose. Do not abuse the tool

. Do 

not use as a hammer, stamp or engrave 
information onto parts, drop or impact 
the tool or otherwise apply excess force 
to the tool in use. Do not mount the 
tool to stands or modify it for stationary 
use.

13. 

Do not carry tool by the air hose. 

Only 

carry the tool by the handle with your 
fi nger off of the trigger.

14. 

Do not use this tool without the 
safety warning label in place

. If the 

label is damaged or missing, contact 

MILWAUKEE

 for a free replacement.

1. 

Use air supply hoses with a minimum 
working pressure rating of 200 psi.

2.

  Use pressure regulators to limit the 

air pressure supplied to the tool. Set 
the regulators to no more than 120 
psi.

3. 

Install only hose couplings that will 
allow all pressure to be removed from 
tool when disconnected from the 
source

. If the wrong fi tting is installed, 

pressure may remain in the tool after 
disconnection, allowing it to drive a 
fastener, possibly causing injury.

4. 

Prior to each use, check workpiece 
contact and trigger for correct op-
eration

. Do not disassemble or clamp 

parts of the workpiece contact, trigger, 
or driving mechanism. This will cause 
unexpected actuation, resulting in seri-
ous injury.

5. 

Never point the discharge area of the 
tool at any body parts or at other peo-
ple

. Always assume the tool is loaded 

and capable of driving a fastener.

6. 

Do not actuate the tool into free 
space

. Do not engage in horseplay. 

The discharged fasteners are projectiles 
capable of causing serious injury.

7. 

When using the tool, ensure the 
workpiece contact is securely placed 
on the workpiece

. Hold the tool fi rmly 

and be prepared for the recoil.

tool or serious injury to persons. Use 
only clean, dry, regulated compressed 
air at the rated pressure or within the 
rated pressure range as marked on the 
tool. Prior to using the tool, always verify 
that the air source has been adjusted to 
the rated air pressure or within the rated 
air-pressure range. Air compressors 
should comply with ANSI B19.3.

28. 

DANGER: Do not use oxygen, com-
bustible gases or bottled gases

 as a 

power source for this tool. The tool will 
explode and cause death or serious 
injury.

29. 

Never connect to an air source that 
is capable of exceeding 200 psi. 

Over 

pressurizing the tool may result in burst-
ing, abnormal operation, breakage of the 

AIR SOURCE

Summary of Contents for 7120-21

Page 1: ...MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR Cat No No de cat 7120 21 TO REDUCE THE RISK OF INJURY USER MUST READ OPERATOR S MANUAL AFIN DE RÉDUIRE LES RISQUES DE BLESSURES L UTILISATEUR DOIT LIRE LE MANUEL DE L OPÉRATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DEBE LEER EL MANUAL DEL OPERADOR ...

Page 2: ...ise is able to cause hearing loss 14 Do not carry an air hose or a tool con nected to an air hose when climbing ladders rigging or scaffolding Do not attach an air hose or tool con nected to an air hose to your body when working at elevated heights At tach the hose to the structure to reduce the risk of loss of balance and injury if the hose shifts 15 Always assume that the tool contains fasteners...

Page 3: ... and edges or penetrate through thin material making them projectiles capable of causing serious injury 12 Use the tool only for the intended purpose Do not abuse the tool Do not use as a hammer stamp or engrave information onto parts drop or impact the tool or otherwise apply excess force to the tool in use Do not mount the tool to stands or modify it for stationary use 13 Do not carry tool by th...

Page 4: ...mance and frequent maintenance 2 3 drops of air tool lubricant Fig 1 3 8 NPT quick connector Adjusting Removing Shingle Guide To adjust the shingle guide press in the guide button and slide the guide to the de sired location To remove the guide press in the guide button and slide it toward the nose of the tool and off of the track 10 8 6 Air inlet 7 Magazine cover 8 Depth of drive adjustment 9 Fas...

Page 5: ...y magazine is empty Fastener door lever Pallet 4 Open the magazine cover 5 Position the pallet to the correct nail height for the coil to be used Read the corresponding nail size on the back of the magazine If the size is not cor rect pull up on the pallet and rotate it clockwise for shorter nails or counter clockwise for longer nails Verify that the correct nail size is set 6 Place the center of ...

Page 6: ...on does not fit all operators in the same way Make sure the eye protection chosen has side shields or provides protection from flying debris both from the front and sides The employer is responsible for enforcing the use of eye protection by the opera tor and other people in the work area When required wear head protection in accordance with ANSI Z89 1 Contact Actuation Operation 1 Grip the handle...

Page 7: ...must not leak from the tool Without pulling the trigger press the workpiece contact against a workpiece The tool must not operate Holding the workpiece contact away from the workpiece pull and hold the trigger for 5 seconds The tool must not operate Continue to pull and hold the trigger and push the workpiece contact against a workpiece The tool must not operate Without pulling the trigger press t...

Page 8: ... LIMITED WARRANTY Use MILWAUKEE fasteners with the following specifications Length 0 75 to 1 75 Collation Angle 15 Size diameter 0 120 Air Tool Oil Synthetic formula for all season performance 4 oz bottle Cat No 49 32 7100 16 oz bottle Cat No 49 32 7105 Quick Connectors Every MILWAUKEE tool is tested before leaving the factory and is warranted to be free from defects in material and workmanship MI...

Page 9: ...ue de protection contre la poussière de chaussures de sécurité antidérapantes et d un casque de chan tier réduit le risque de blessures 12 L opérateur et toutes les personnes se tenant dans l aire de travail doi vent porter un masque de protection conformément à la norme ANSI Z87 1 Le masque de protection ne s adapte pas de la même façon sur tous les opérateurs Veiller à ce que la protection chois...

Page 10: ...es 10 Ne jamais approcher les mains et le corps de la zone de décharge de l outil Ne jamais déblocage d une élé ment de commande de fonctionnement en tenant la zone de décharge de l outil Les attaches déchargées par l outil peuvent causer de graves blessures si elles touchent les mains ou le corps 11 Ne pas enfoncer d attache près du bord de la pièce de bois Les attaches peuvent glisser et ressort...

Page 11: ...ispositifs d actionnement en séquence ou par contact Attache Une agraphe une broche un clou une pointe ou un autre type d attache conçu et fabriqué pour une utilisation avec ces outils Blocage Obstruction dans les zones d alimentation ou d insertion de l outil Elément de contact avec la pièce de bois Un élément de commande de fonctionnement de l outil activé par la pièce de bois à soli dariser Con...

Page 12: ...ils pneumatiques 4 Rattacher la conduite d air au raccord rapide 5 Vérifier l absence de fuites d air REMARQUE Pour améliorer la qualité du joint entre le raccord et l outil et empêcher la formation de rouille appliquer du ruban ou une pâte PTFE sur le filetage du raccord avant de l insérer Connexion de la prise d air 2 à 3 gouttes de lubrifiant pour outils pneumatiques Connecteur rapide 3 8 pouce...

Page 13: ...reposer sur la tringle de clouage REMARQUE N utiliser que des fixations de taille de longueur d angle d assemblage et de tête appropriés comme indiqué sur la plaque signalé tique de l outil 7 Tirer l extrémité libre de la bobine vers l avant de l outil Insérer les têtes de clous à plat dans la fente pour clous Pousser le premier clou au delà du mécanisme d alimentation dans l avant de l outil 8 Fe...

Page 14: ...e les risques de perte d équilibre et les blessures causées par le mouvement éventuel de la conduite Fig 7 Actionnement en séquence Fig 8 Actionnement par contact Mode d actionnement en séquence 1 Tenir fermement le manche 2 Positionner l embout de l outil sur la surface de travail 3 Presser l outil contre la surface de tra vail L élément de contact de la pièce de bois est ainsi comprimé 4 Appuyer...

Page 15: ...util tous les jours avant de commencer à travailler ou en cas de chute de coup d écrasement etc de l outil Réaliser les vérifications suivantes DANS L ORDRE INDIQUÉ Si l outil ne fonctionne pas correctement contacter immédiatement un agent de réparation MILWAUKEE Toujours diriger l outil en direction opposée à soi et aux autres 1 Débrancher la prise d air de l outil et retirer la bande d attaches ...

Page 16: ...u consulter le site Web à l adresse www milwaukeetool com Pour obtenir un catalogue contacter le distributeur local ou un centre d entretien AVERTISSEMENT Déconnecter toujours la prise d air de l outil et enlever les bandes d attache avant de remplacer ou d enlever les accessoires N utiliser que les accessoires spécialement conçus pour cet outil Les acces soires non recommandés peuvent présenter d...

Page 17: ...tección contra fragmentos suspendidos en el aire tanto en la parte delantera como en los late rales El empleador es responsable de imponer al operador y a otras personas en el área de trabajo el uso de la protec ción ocular Cuando sea necesario use protección para la cabeza de acuerdo con ANSI Z89 1 13 Siempre use protectores auditivos cuando utiliza la herramienta por períodos prolongados La expo...

Page 18: ...e altere ni haga de cualquier otra forma que los controles de fun cionamiento dejen de funcionar Esto causará un funcionamiento imprevisto que puede provocar lesiones graves 28 PELIGRO No utilice oxígeno gases combustibles ni gases envasados como fuente de energía para esta herra mienta La herramienta explotará y pro vocará la muerte o lesiones graves 29 Nunca la conecte a una fuente de aire capaz...

Page 19: ... ac cionamiento accionamiento secuencial único o accionamiento por contacto Sujetador Una grapa clavija punta clavo u otro dispositivo de fijación que está diseñado y fabricado para ser utilizado con las her ramientas Atoramiento Una obstrucción en las áreas de aliment ación o de disparo de la herramienta Contacto de la pieza de trabajo Un elemento del control de funcionamiento en la herramienta d...

Page 20: ...mienta al suminis tro de aire controle el calibrador regulador del compresor de aire para asegurarse de que funciona correctamente en un rango de entre 4 8 y 8 3 BAR La presión de aire superior a 8 3 BAR puede causar lesiones y daños a la propiedad La presión correcta es la presión más baja necesaria para realizar el trabajo Para conectar el suministro de aire 1 Quite el tapón de plástico de la en...

Page 21: ...y otros 2 Desconecte el suministro de aire de la herramienta 3 Abra el sujetador de puerta presionando la palanca de la puerta y levantándola 4 Abra la cubierta del cargador 5 Para retirar un rollo de sujetadores deslice el rollo fuera de los montantes para tarima y fuera de la ranura para clavos 6 Vuelva a cargar siguiendo las instruc ciones Cómo instalar las tiras de sujetadores Para evitar lesi...

Page 22: ...o de pérdida del equilibrio y lesiones si la manguera se mueve ADVERTENCIA ADVERTENCIA Fig 7 Accionamiento secuencial único Fig 8 Accionamiento por contacto Funcionamiento de accionamiento se cuencial único 1 Sujete muy bien el mango 2 Ubique la punta de la herramienta en la superficie de trabajo 3 Empuje la herramienta contra la superfi cie de trabajo comprimiendo el contacto de la pieza de traba...

Page 23: ... de la herramienta Apriete todos los sujetadores que estén flojos 3 Presione el contacto de la pieza de trabajo contra la misma Se debe mover con facilidad 4 Con el contacto de la pieza trabajada presionado contra la pieza tire del gatillo Se debe mover con facilidad 5 Conecte el suministro de aire a 4 8 BAR en la herramienta NO cargue la tira de sujetadores 6 Seleccione el funcionamiento de accio...

Page 24: ...tool com en Internet Para obtener un catálogo póngase en contacto con su distribuidor local o con un centro de reparaciones ADVERTENCIA Desconecte siempre el suministro de aire de la herramienta y quite las tiras de sujetadores antes de cambiar o retirar accesorios Use solamente accesorios específicamente reco mendados para esta herramienta El uso de otros puede resultar peligroso Todas las herram...

Page 25: ...fax 1 800 638 9582 email metproductsupport milwaukeetool com Monday Friday 8 00 AM 4 30 PM Central Time Canada Service MILWAUKEE Milwaukee Electric Tool S A de C V Blvd Abraham Lincoln no 13 Colonia Los Reyes Zona Industrial Tlalnepantla Edo México C P 54073 Tel 55 5565 1414 Fax 55 5565 6874 Adicionalmente tenemos una red nacional de distribuidores autorizados listos para ayudarle con su herramien...

Reviews: