For rated flows under free flow conditions, the head is measured at a point upstream referenced to the
beginning of the converging section. Refer to the following table.
Position the transducer such that it is centered over the flow at a minimum height of 60 cm ( 2ft ) above the
maximum head.
Flume Size
Point of Measurement
(pipe dia. in inches)
mm
inches
4 - 12
25
1.0
15
32
1.3
18
38
1.5
21
44
1.8
24
51
2.1
30
64
2.5
36
76
3.0
42
89
3.5
48
102
4.0
54
114
4.5
60
127
5.0
66
140
5.5
72
152
6.0