7ML19981CR01
Milltronics Weight Lifter MWL – Instruction Manual
Page 25
4.
Clamp the bottom of the idler support angle-brackets to the dynamic beam, using
two C-clamps.
5.
Remove the four socket flat-head bolts that secure the idler support angle-brackets.
6.
Mount the new calibration-weight brackets using the same holes as the idler
support angle brackets. Use the new bolts and nuts supplied with the MWL, and
hand-tighten the nuts.
7.
Align the new calibration-weight brackets with each other vertically and
horizontally.
8.
Tighten the nuts and bolts firmly to secure all four brackets. Torque value = 54.6 Nm
(40 ft-lbs.)
9.
Remove the C-clamps.
10. Re-install the idler and check idler alignment as described in the Belt Scale
Instruction Manual.
11. Free the weighing mechanism: loosen screws A and rotate the 2 shipping stops
inward and down, over screws B (See step 1, page 24). Tighten screws A to secure
them in place.
Calibration weight
bracket
Angle-bracket
Dynamic beam
C-clamp
MWL-d2.fm Page 25 Tuesday, June 12, 2001 9:34 AM