Operation
Applying calibration weights
Simply turn the crank handle until the calibration weights are fully lowered onto the
calibration-weight supports of the belt scale. (Please see the manuals for the Milltronics
Belt Scale and the Integrator, for the appropriate calibration procedures.)
Storing calibration weights
After you have completed the scale calibration procedure, turn the crank handle until the
lifting-pads are fully raised.
Storing crank handle
Remove the crank handle and store it. (See next page for details.)
Note:
To ensure accurate calibration, you must keep the area between the MWL
lifting pads and the calibration weights clear of buildup during the calibration routine.
(See Maintenance procedures on page 19.)
Lifting pads down
Flat bar calibration
weights applied
Calibration-weight supports (2)
Lifting-pads
raised
Crank Handle stored on far side of
Crank Body, with locking ball-pin
MWL48all.fm Page 17 Tuesday, June 12, 2001 8:23 AM