Page 24
Milltronics Weight Lifter MWL – Instruction Manual
7ML19981CR01
1.
Rotate the shipping stops on the MSI into a vertical position, and tighten screws A
to secure the stops in place. This will help to protect the load cells from damage
while the calibration-weight brackets are being installed.
2.
Remove the idler.
3.
Remove the two socket-head cap-screws that secure the calibration-weight bar,
then remove the calibration-weight bar from the dynamic beam of the belt scale.
Note:
Take care to protect the load cells from impact or prying forces during
installation of the new calibration-weight brackets.
Shipping stop in
free position
Shipping stop in
free position
Screws
A
Screws
B
Bolts - (step 6)
Idler removed
Calibration-weight bar removed
Calibration-weight brackets
Shipping stops in
vertical position
MWL48all.fm Page 24 Tuesday, June 12, 2001 8:23 AM