background image

OM-212296 Page 37

SECTION 12 − PARTS LIST

.

Hardware is common and
not available unless listed.

803 627-D

1

2

3

4

5

6

7

14

15

16

17

18

22

23

24

20

19

13

8

9

10

11

12

21

Figure 12-1. Control Box Assembly

Description

Part

No.

Dia.

Mkgs.

Item

No.

Figure 12-1 Control Box Assembly

Quantity

1

214 799

Box, Enclosure

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

214 808

Cover, Box Enclosure

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

179 851

Knob, Pointer 1.670 Dia X .250 Id Push On W/Spring

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . .

4

PB3, 4

202 944

Switch, Pb Mc No Spst 5A 115VAC (Gray)

2

. . .

. .

.

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . .

5

PB1

202 946

Switch, Pb Mc No Spst 5A 115VAC (Green)

1

. . .

. . .

. .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . .

6

PB2

202 945

Switch, Pb Mc No Spst 5A 115VAC (Red)

1

. . .

. . .

. .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Nameplate (Order by Model and Serial Number)

1

. . .

. . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . .

8

S1

011 611

Switch, Tgl Dpdt 15A

1

. . .

. . . .

. .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

236 564

Overlay, Front Panel (CE)

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

238 273

Circuit Card Assy, Switches

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

250 508

Circuit Card Assy, Display/Micro W/Program

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . .

12

221 404

XFMR, Control 30Va 24V/24V/18V/18V 115 Pri 50/60

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . .

13

193 440

Switch, Ground Current Sensor

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

214 816

Spacer, Terminal Strip Bracket

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

212 481

Block, Term 20 Amp 13 Pole Screw Term

2

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . .

16

214 805

Bracket, Terminal Strip

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

230 939

Label, Terminal Strip

1

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

PC1

242 297

Circuit Card Assy, Motor Control W/Program

1

. . .

. . .

. .

. . . . .

. . . . . . . . . . . . . . . . . . . . . . . .

19

RC2

139 268

Conn, Circ Ms/Met 10Skt Size 18 Rcpt Panel Solder

1

. . .

. . .

. .

. . . . .

. . . . . . . . . . . . . . . . .

20

RC1

094 480

Conn, Circ Ms/Met 14Pin Size 20 Rcpt Panel Solder

1

. . .

. . .

. .

. . . . .

. . . . . . . . . . . . . . . . .

21

RC3

073 687

Conn, Circ Ms/Met 4Skt Size 14S Rcpt Panel Solder

1

. . .

. . .

. .

. . . . .

. . . . . . . . . . . . . . . . .

22

070 371

Blank, Snap-In Nyl 1.093/1.125 Mtg Hole Black

2

. . .

. . . . . . . . . .

. . . . .

. . . . . . . . . . . . . . . . . . . . . .

23

CB1

083 432

Circuit Breaker, Man Reset 1P 10A 250VAC Frict

1

. . .

. . .

. .

. . . . .

. . . . . . . . . . . . . . . . . . . .

Summary of Contents for HDC 1500DX

Page 1: ...escription OM 212 296Y 2016 06 28 Submerged SAW Welding Submerged Arc Controller For Automatic Welding HDC 1500DX File SUBMERGED SAW For product information Owner s Manual translations and more visit...

Page 2: ...ntinue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to help you get...

Page 3: ...mental Specifications 11 SECTION 5 INSTALLATION 12 5 1 Typical Equipment Location 12 5 2 Mounting Hole Layout 12 5 3 Typical Connection Diagram With Miller Power Sources 13 5 4 Left Side Panel Connect...

Page 4: ...M SELECT 31 SECTION 8 MOTOR TYPES 31 SECTION 9 SETTING SEQUENCE PARAMETERS 32 9 1 Sequence Parameters In A Program 32 SECTION 10 MAINTENANCE TROUBLESHOOTING 33 10 1 Routine Maintenance 33 10 2 Circuit...

Page 5: ...neeling or lying or when there is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following equipment in order presented 1 a semiautomaticDC...

Page 6: ...ared according to AWS F4 1 and AWS A6 0 see Safety Standards D Do not weld where the atmosphere can contain flammable dust gas or liquid vapors such as gasoline D Connect work cable to the work as clo...

Page 7: ...S can injure D Keep away from moving parts such as fans D Keep all doors panels covers and guards closed and securely in place D Have only qualified persons remove doors panels covers or guards for ma...

Page 8: ...PA Standard 51B from National Fire Protection Association Quincy MA 02269 phone 1 800 344 3555 website www nfpa org OSHA Occupational Safety and Health Standards for General Indus try Title 29 Code of...

Page 9: ...s dans un environnement humideou si l on porte des v tements mouill s sur des structures m talliquestelles que sols grilles ou chafaudages en position coinc e comme assise genoux ou couch e ou s il y...

Page 10: ...br lures Le contact accidentel de l lectrode avec des objets m talliques peut provoquer des tincelles une explosion un sur chauffement ou un incendie Avant de commencer le soudage v rifier et s assur...

Page 11: ...areil D Tenir l quipement c bles et cordons distance des v hicules mobiles lors de toute op ration en hauteur D Suivre les consignes du Manuel des applications pour l quation de levage NIOSH r vis e P...

Page 12: ...ational Electrical Code NFPA Standard 70 from National Fire Protec tion Association Quincy MA 02269 phone 1 800 344 3555 website www nfpa org and www sparky org Safe Handling of Compressed Gases in Cy...

Page 13: ...ur local distributor for further information Safe37 2012 05 3 2 Symbols And Definitions Some symbols are found only on CE products A Amperage Remote Output Hz Hertz V Volts Start Time Input Single Pha...

Page 14: ...l Location The serial number and rating information for this product is located on the side Use rating label to determine input power requirements and or rated output For future reference write serial...

Page 15: ...o 104 F 10 to 40 C 4 to 131 F 20 to 55 C IP21 2014 06 B Information On Electromagnetic Compatibility EMC This Class A equipment is not intended for use in residential locations where the electrical po...

Page 16: ...Ref 131 138 A 1 Welding Power Source 2 Side Beam 3 Weld Control 4 Spool Support 5 Wire Drive Assembly 6 Automatic Welding Gun 1 2 6 3 4 5 5 2 Mounting Hole Layout Ref 803 021 B 8 in 203 mm 10 3 4 in 2...

Page 17: ...lding power source and weld control and disconnect input power before making connections Use remote voltage sense leads in all applications Suggested size remote voltage sense wire is 12 gauge or high...

Page 18: ...nal terminal blocks 4 4 Pin Receptacle Connection To Flux Hopper Shielding Gas Valve 5 14 Pin Receptacle Connection To Welding Power Source 6 10 Pin Receptacle Connection to Wire Drive Motor To connec...

Page 19: ...lock TB2 3 Terminal Block TB1 4 Securing Screw Terminal Block 5 Stripped Lead 6 Typical Lead Being Connected To Terminal Block 7 Access Hole Used For Connections To Terminal Blocks Flux Valve etc Inst...

Page 20: ...Remote Jog Down When connected to remote common jogs wire down Remote Common Circuit common for remote capabilities 5 7 Terminal Block TB2 Connection Information Terminals Function Information Red 115...

Page 21: ...inal Block TB2 3 Access Hole Used For Connections To Terminal Blocks Flux Valve etc Install strain relief customer supplied in access hole Strip 1 4 in 6 mm insulation off end of leads Insert four con...

Page 22: ...power source present whenever power source is On B B Normally open set of relay contacts connect A to B when Start is pressed and preflux timer has timed out Remote Output Control C C Remote command...

Page 23: ...a TB2 Terminal Socket Information Flux Hopper Hookups A Red 115 volts AC to power flux hopper B Black Switched 115 volts AC to power flux hopper C White Circuit common for 115 volts AC for flux hopper...

Page 24: ...nse leads are out of the current paths Sense leads detect arc voltage ac curately Best starts arcs and most reliable results BAD Sense lead is affected by weld current Due to voltage drops across work...

Page 25: ...rops across work piece arc voltage may be low causing need for deviation from standard procedures BAD Current flow from lead affects trail sense Current flow from trail affects lead sense Neither sens...

Page 26: ...age accurately No voltage drop between lead and trail sense Best starts arcs and most reliable results Work Clamp Trail Lead Trail Lead 5 13 Remote Voltage Sense Leads Placement Guidelines For Multipl...

Page 27: ...a power source selection the operator may press the Program Button to avoid having to wait the five seconds When turning off the controller the selected power source will be retained Next Time Contro...

Page 28: ...cycle 6 1 Power Switch And Buttons 803 448 A 1 Power Switch 2 Start Button 3 Stop Button 4 Inch Up Button 5 Inch Down Button 2 3 1 5 4 6 2 Program Push Buttons 1 Program Display The number of the acti...

Page 29: ...The upper display push button LED illumi nates to indicate that information displayed can be changed with the Adjust control 4 Volts LED 5 Time LED The LED s below the display illuminate to in dicate...

Page 30: ...ive The Adjust control can be used to change the setting from AUTO to a run in wire speed setting If a start condi tion is set run in is a percentage of the start wire speed otherwise run in is a perc...

Page 31: ...nce push button flashes and the Start LEDs flash In this condition the unit is in the Start sequence display mode and Start se quence parameters are shown in the dis plays When the Sequence push butto...

Page 32: ...lso turn off the password code feature 2 Power Source Selection The upper display shows PSS The lower display shows ON or OFF Use Adjust control to select ON or OFF 3 Voltage Range Lock Voltage range...

Page 33: ...SB1 will engage when the start button is pressed and preflux has timed out When a positive time is selected SB1 will engage when the selected time has elapsed after an arc is es tablished When a nega...

Page 34: ...the gas flow function and CV C mode is not available The Flux button now controls the gas flow Refer to section 6 9 for op erating instructions 6 12 Operation Of HDC In GMAW MIG Mode 1 4 Ref 803 449...

Page 35: ...ollowing table Program Selected RC24 Pin 1 to Pin 2 RC26 Pin 1 to Pin 2 Program 1 Not Connected Not Connected Program 2 Not Connected Connected Program 3 Connected Not Connected Program 4 Connected Co...

Page 36: ...et to zero in any timed se quence except Weld the sequence is skipped Sequence Parameters Volts CV or CV C Amps CV C Wirespeed CV Seconds 1 Preflow 2 Run In 3 Start 4 Weld 5 Crater 6 Burnback 7 Postfl...

Page 37: ...14 pin cord Check gas hose and fittings Check gun cable Replace cracked parts 6 Months Blow out or vacuum inside During heavy service clean monthly OR Clean drive rolls 10 2 Circuit Breaker CB1 Turn...

Page 38: ...amps for the unit to go from run in to weld parameters Have Factory Authorized Service Agent check control board PC1 and replace if necessary No contactor control for welding power source ensure that...

Page 39: ...any grounded equipment Turn the unit off for 10 seconds to clear the error message Separate welding cables from control cables Noise is creating an excessive amount of current in the safety ground Un...

Page 40: ...OM 212296 Page 36 SECTION 11 ELECTRICAL DIAGRAM 238 416 A Figure 11 1 Circuit Diagram...

Page 41: ...011 611 Switch Tgl Dpdt 15A 1 9 236 564 Overlay Front Panel CE 1 10 238 273 Circuit Card Assy Switches 1 11 250 508 Circuit Card Assy Display Micro W Program 1 12 221 404 XFMR Control 30Va 24V 24V 18...

Page 42: ...h 1 236 767 Label CB1 1 236 565 Label Warning Electric Shock Power Still Present 1 236 569 Label Rating Card CSA CE 300438 1 236 226 Label Remote Connections 1 212 591 Cable Motor 10 Ft 10 Pin 1 178 8...

Page 43: ...ns and Subarc SAW Torches Remote Controls and RFCS RJ45 Replacement Parts No labor Roughneck Guns Spoolmate Spoolguns Miller s True Blue Limited Warranty shall not apply to 1 Consumable components suc...

Page 44: ...your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal Safety Equip...

Reviews: