OM-212296 Page 30
!
Turn Off welding power
source and weld control, and
disconnect input power be-
fore opening access door.
1
Screws (3)
2
Access Door
Remove screws and open access
door.
3
Switch (S1)
Place switch one in on position.
4
Front Display Board
Close access door and reinstall
screws.
Connect power and turn on unit.
.
If there is no activity for five
seconds the controller will
automatically default to the
previously selected power
source.
See table for available MIG power
sources and motors.
In MIG mode your menu will now
display the gas flow function and
CV+C mode is not available.
The Flux button now controls the
gas flow. Refer to section 6-9 for op-
erating instructions.
6-12. Operation Of HDC In GMAW (MIG) Mode
1
4
Ref. 803 449-B / 805 080-A
RC2
RC1
RC3
Power Source
Upper Display
Lower Display
Deltaweld 452
DELT
452
Deltaweld 652
DELT
652
Dimension 452
DIM
452
Dimension 652
DIM
652
Subarc DC 650
DC
650
Subarc DC 800
DC
800
XMT 304
XMT
304
XMT 350
XMT
350
XMT 456
XMT
456
Invision 456 MP
l456
MP
Invision 456 P
l456
P
Phoenix 456
PHX
456
3
2
MIG Motor Options
Saw 4
Rad 400, Rad 780 with no tach
12
345678
O
N
1 MIG Function
2 No Function
3 No Function
4 No Function
5 No Function
6 No Function
7 No Function
8 No Function
MIG Power Sources And Motors