Trouble
OM-244 814 Page 53
SECTION 12
−
TROUBLESHOOTING
12-1. Troubleshooting
Trouble
Remedy
No weld output; completely inoperative
Place line disconnect in On position (see Section 8-10).
Check and replace line fuse(s), if necessary, or reset circuit breaker
(see Section 8-10).
Check for proper input power connections (see Section 8-10).
No weld output; meter display on with no
error displayed.
Check to see if the contactor indicator light is lit when contactor line is asserted on.
Erratic or improper weld output with no
errors displayed.
Use proper size and type of weld cable (see Section 9-2).
Clean and tighten all weld connections.
No 115 volts AC at the duplex
receptacle.
Reset supplementary protector CB1 (see Section 8-6).
Wire does not feed.
Check supplementary protector CB2 and reset if necessary (see Section 8-6).
Check motor control cable connections.
Wire feeds erratically.
Readjust hub tension.
Readjust drive roll pressure.
Clean or replace dirty or worn drive rolls.
Remove weld spatter around the nozzle opening.
Replace contact tip or liner. See gun Owner’s Manual.
Check motor control cable connections.
Wire feeds as soon as power is supplied. Check gun trigger. See gun Owner’s Manual.
Wire stubbing on low end using a
constant current power source.
Increase output setting of the power source.
Check voltage sense lead connection, clean and tighten if necessary.
Gas does not flow or does not stop
flowing; wire feeds.
Check gas valve and flow meter.
Wire burns back to gun contact tip when
using electrode negative (straight
polarity) process.
Check to be sure that volt sense lead is connected to the work.
12-2. Check Web Message Display
When an existing Axcess power source is upgraded to an Axcess E, the first time the unit is powered up the message CHCK WEB will appear on the
display (see Figure 1).
CHCK
WEB
Trigger Control
Program
Process
Wire Type
Gas Type
Process Set up
Volts
Time
Arc Adjust
WFS
Amps
Arc Ctl
Sequence
Trigger Hold
Adjust
Feeder Set Up
1
Figure 1. Feeder Display On First Power Up After Upgrade
Summary of Contents for Axcess E 300
Page 14: ...OM 244 814 Page 10 ...
Page 18: ...OM 244 814 Page 14 Notes ...
Page 22: ...OM 244 814 Page 18 Notes ...
Page 26: ...OM 244 814 Page 22 Notes ...
Page 30: ...OM 244 814 Page 26 Notes ...
Page 56: ...OM 244 814 Page 52 Notes ...
Page 63: ...Trouble OM 244 814 Page 59 Notes ...
Page 68: ...OM 244 814 Page 64 Figure 14 2 Circuit Diagram For Axcess E 300 2 Of 2 ...
Page 69: ...Circuits OM 244 814 Page 65 248 763 E Part 2 Of 2 ...
Page 70: ...OM 244 814 Page 66 Figure 14 3 Circuit Diagram For Axcess E 450 1 Of 2 ...
Page 71: ...Circuits OM 244 814 Page 67 245 131 F Part 1 Of 2 ...
Page 72: ...OM 244 814 Page 68 Figure 14 4 Circuit Diagram For Axcess E 450 2 Of 2 ...
Page 73: ...Circuits OM 244 814 Page 69 245 131 F Part 2 Of 2 ...
Page 74: ...OM 244 814 Page 70 Figure 14 5 Circuit Diagram For Axcess E 675 1 Of 2 ...
Page 75: ...Circuits OM 244 814 Page 71 250 570 C Part 1 Of 2 ...
Page 76: ...OM 244 814 Page 72 Figure 14 6 Circuit Diagram For Axcess E 675 2 Of 2 ...
Page 77: ...Circuits OM 244 814 Page 73 250 570 C Part 2 Of 2 ...
Page 78: ...OM 244 814 Page 74 Figure 14 7 Circuit Diagram For Axcess E Module ...
Page 79: ...Circuits OM 244 814 Page 75 250 571 C ...
Page 80: ...OM 244 814 Page 76 Notes ...
Page 106: ...Notes ...