OM-244 814 Page 58
C. General Purpose LEDs
D17
On
Gnd Cnt
−
Indicates ground error. Contact nearest factory Authorized Service Agent.
Off
Indicates no error
D25
On
OVR CNT
−
Indicates an error. Contact nearest factory Authorized Service Agent.
Off
Indicates no error
D26
On
OVR PWR
−
Indicates unit is operating at max input current. Contact nearest factory Authorized Service
Agent.
Off
Indicates no error
D28
— —
Future use
— —
D30
On
OVR TMP
−
Indicates unit is overheated. Turn unit off and allow to cool. If error continues, contact nearest
factory Authorized Service Agent.
Off
Indicates no error
D33
On
Contactor
−
Indicates unit is receiving a contactor On signal
Off
Indicates contactor on signal is not being received. Check input connections.
D43
On
ARM/O
−
Ind10 VDC is present, should flash at same rate as ARM AWAKE
Off
Ind10 VDC is not present
D44
On
E-Stop
−
Indicates E-Stop is not present
Off
Indicates E-Stop has been engaged, check external sources
D98
On
USB Host on
−
Indicates this function is operating properly
Off
Indicates USB error. Cycle unit power, if error is still present contact nearest factory Authorized Service
Agent
D101
On
Ind2.5 VDC is present
Off
Ind2.5 VDC is not present
D108
On
Ind25 VDC is present
Off
Ind25 VDC is not present
12-6. Network And Module Status LEDs
A.
Network Status LED
LED2 on the E Module board stack
Status
Diagnosis
Off
The board stack is not on-line with the network or there is no power applied to the board stack.
Green
The board stack is operating normally and the on-line connection is made with the network.
Flashing Green
The board stack is waiting for an on-line connection to be made with the network.
Red
The board stack has encountered a communication link failure with the network. Check DeviceNet cable connections. Replace
board stack if necessary.
B.
Module Status LED
LED1 on the E Module board stack
Status
Diagnosis
Off
There is no power applied to the board stack or the board stack software is not executing its functions.
Green
The board stack is operating normally.
Flashing Red
The board stack has encountered a recoverable fault. Wait or cycle power to clear fault.
Red
The board stack has encountered an unrecoverable fault.
Summary of Contents for Axcess E 300
Page 14: ...OM 244 814 Page 10 ...
Page 18: ...OM 244 814 Page 14 Notes ...
Page 22: ...OM 244 814 Page 18 Notes ...
Page 26: ...OM 244 814 Page 22 Notes ...
Page 30: ...OM 244 814 Page 26 Notes ...
Page 56: ...OM 244 814 Page 52 Notes ...
Page 63: ...Trouble OM 244 814 Page 59 Notes ...
Page 68: ...OM 244 814 Page 64 Figure 14 2 Circuit Diagram For Axcess E 300 2 Of 2 ...
Page 69: ...Circuits OM 244 814 Page 65 248 763 E Part 2 Of 2 ...
Page 70: ...OM 244 814 Page 66 Figure 14 3 Circuit Diagram For Axcess E 450 1 Of 2 ...
Page 71: ...Circuits OM 244 814 Page 67 245 131 F Part 1 Of 2 ...
Page 72: ...OM 244 814 Page 68 Figure 14 4 Circuit Diagram For Axcess E 450 2 Of 2 ...
Page 73: ...Circuits OM 244 814 Page 69 245 131 F Part 2 Of 2 ...
Page 74: ...OM 244 814 Page 70 Figure 14 5 Circuit Diagram For Axcess E 675 1 Of 2 ...
Page 75: ...Circuits OM 244 814 Page 71 250 570 C Part 1 Of 2 ...
Page 76: ...OM 244 814 Page 72 Figure 14 6 Circuit Diagram For Axcess E 675 2 Of 2 ...
Page 77: ...Circuits OM 244 814 Page 73 250 570 C Part 2 Of 2 ...
Page 78: ...OM 244 814 Page 74 Figure 14 7 Circuit Diagram For Axcess E Module ...
Page 79: ...Circuits OM 244 814 Page 75 250 571 C ...
Page 80: ...OM 244 814 Page 76 Notes ...
Page 106: ...Notes ...