General
OM-244 814 Page 47
Trouble
Remedy
Probable Cause
Wandering, hunting or erratic arc
(Continued)
Voltage sensing leads open or shorted
Repair or replace voltage sense leads
High frequency noise in the area
Be sure proper grounding methods are followed
when TIG or plasma equipment is used in the area
Arc blow
Drive motor tachometer or motor cable open or
shorted
Check drive motor tachometer and cables, and re-
pair or replace
Wrong size drive rolls
Replace with proper size drive rolls
Too much or too little drive roll pressure
Adjust drive roll pressure
Welding wire burns back to contact tip at
the start of a weld
Restriction in wire feed system
Check inlet cable, gun liner and wire guides
Worn drive rolls
Replace drive rolls
Wrong size drive rolls
Replace with proper size drive rolls
Improper start parameters
Adjust start parameters
Worn contact tip
Replace contact tip
Wrong size or type of contact tip
Replace with proper size and type contact tip
Not enough cast in welding wire
Add a wire straightener to put cast in wire
Welding wire burns back to contact tip
during welding
Restriction in wire feed system
Check inlet cable, gun liner and wire guides
Worn drive rolls
Replace drive rolls
Wrong size drive rolls
Replace with proper size drive rolls
Too much or too little drive roll pressure
Adjust drive roll pressure
Worn contact tip
Replace contact tip
Wrong size or type of contact tip
Replace with proper size and type contact tip
Not enough cast in welding wire
Add a wire straightener to put cast in wire
Welding wire burns back to contact tip at
the end of a weld
Welding power source output not shutting off
Make sure all switches are in correct position, re-
pair power source if necessary
Burnback setting too high or too long
Adjust burnback setting or turn off completely
Shutdown at arc initiation using power
source and feeder or interface
No voltage feedback signal
Broken or disconnected voltage feedback lead, no
open circuit voltage, check power source
No current feedback signal
Poor parameters, open in weld circuit, faulty hall
device, check power source
No tachometer sensing
No wire speed command from robot, material
jammed in drive gears, faulty tachometer in drive
motor, wire feed drive circuit board, or motor cable,
check wire feed system
Poor parameters preventing arc stability
Check for proper pulse program, material, welding
wire, shielding gas, voltage setting, and wire speed
setting
Arc start error
Check contact tip, wire feed system and weld cir-
cuit
No start signal from robot
Check robot setup and interconnect cable connec-
tion between robot controller and interface
No wire feed with wire feed motor running
Wire stuck in contact tip, worn or wrong size drive
rolls, improper drive roll pressure setting, or wire
not unspooling or restriction in drum adapter, check
wire feed system
Summary of Contents for Axcess E 300
Page 14: ...OM 244 814 Page 10 ...
Page 18: ...OM 244 814 Page 14 Notes ...
Page 22: ...OM 244 814 Page 18 Notes ...
Page 26: ...OM 244 814 Page 22 Notes ...
Page 30: ...OM 244 814 Page 26 Notes ...
Page 56: ...OM 244 814 Page 52 Notes ...
Page 63: ...Trouble OM 244 814 Page 59 Notes ...
Page 68: ...OM 244 814 Page 64 Figure 14 2 Circuit Diagram For Axcess E 300 2 Of 2 ...
Page 69: ...Circuits OM 244 814 Page 65 248 763 E Part 2 Of 2 ...
Page 70: ...OM 244 814 Page 66 Figure 14 3 Circuit Diagram For Axcess E 450 1 Of 2 ...
Page 71: ...Circuits OM 244 814 Page 67 245 131 F Part 1 Of 2 ...
Page 72: ...OM 244 814 Page 68 Figure 14 4 Circuit Diagram For Axcess E 450 2 Of 2 ...
Page 73: ...Circuits OM 244 814 Page 69 245 131 F Part 2 Of 2 ...
Page 74: ...OM 244 814 Page 70 Figure 14 5 Circuit Diagram For Axcess E 675 1 Of 2 ...
Page 75: ...Circuits OM 244 814 Page 71 250 570 C Part 1 Of 2 ...
Page 76: ...OM 244 814 Page 72 Figure 14 6 Circuit Diagram For Axcess E 675 2 Of 2 ...
Page 77: ...Circuits OM 244 814 Page 73 250 570 C Part 2 Of 2 ...
Page 78: ...OM 244 814 Page 74 Figure 14 7 Circuit Diagram For Axcess E Module ...
Page 79: ...Circuits OM 244 814 Page 75 250 571 C ...
Page 80: ...OM 244 814 Page 76 Notes ...
Page 106: ...Notes ...