General
OM-244 814 Page 37
9-2. Selecting Weld Cable Sizes*
NOTICE
−
The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable
size.
Weld Cable Size*** and Total Cable (Copper) Length in Weld Circuit Not Exceeding****
100 ft (30 m) or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Weld Output Terminals
!
Turn off power before
connecting to weld out-
put terminals.
!
Do not use worn, dam-
aged, undersized, or
poorly spliced cables.
Welding
Amperes**
10
−
60%
Duty Cycle
60
−
100%
Duty Cycle
10
−
100% Duty Cycle
Ref. 803 824-A
Positive
)
Negative
*
100
4 (20)
4 (20)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
150
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
200
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0
(120)
4/0
(120)
250
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0
(120)
2 ea. 2/0
(2x70)
2 ea. 2/0
(2x70)
300
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0
(120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
350
1/0 (60)
2/0 (70)
3/0 (95)
4/0
(120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
400
1/0 (60)
2/0 (70)
3/0 (95)
4/0
(120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
2 ea. 4/0
(2x120)
500
2/0 (70)
3/0 (95)
4/0
(120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 3/0
(3x95)
600
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 4/0
(3x120)
3 ea. 4/0
(3x120)
700
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 4/0
(3x120)
3 ea. 4/0
(3x120)
4 ea. 4/0
(4x120)
800
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 4/0
(3x120)
3 ea. 4/0
(3x120)
4 ea. 4/0
(4x120)
4 ea. 4/0
(4x120)
900
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
1000
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
1250
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
4 ea. 3/0
(4x95)
*
This chart is a general guideline and may not suit all applications. If cable overheating occurs, use next size larger cable.
**Cable should be sized for Peak Amperage (Apk) for pulse welding applications.
***Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm
2
for metric use
****For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.
S-0007-E
.
In pulse welding applications using inverter power sources, peak currents can result in extreme voltage drops producing poor welding characteris-
tics with undersized cables. A recommendation for weld cable size is a minimum of 2/0 for 300 ampere welding power sources and 4/0 for 450
ampere welding power sources when total cable length is less than 100 ft (30m).
Summary of Contents for Axcess E 300
Page 14: ...OM 244 814 Page 10 ...
Page 18: ...OM 244 814 Page 14 Notes ...
Page 22: ...OM 244 814 Page 18 Notes ...
Page 26: ...OM 244 814 Page 22 Notes ...
Page 30: ...OM 244 814 Page 26 Notes ...
Page 56: ...OM 244 814 Page 52 Notes ...
Page 63: ...Trouble OM 244 814 Page 59 Notes ...
Page 68: ...OM 244 814 Page 64 Figure 14 2 Circuit Diagram For Axcess E 300 2 Of 2 ...
Page 69: ...Circuits OM 244 814 Page 65 248 763 E Part 2 Of 2 ...
Page 70: ...OM 244 814 Page 66 Figure 14 3 Circuit Diagram For Axcess E 450 1 Of 2 ...
Page 71: ...Circuits OM 244 814 Page 67 245 131 F Part 1 Of 2 ...
Page 72: ...OM 244 814 Page 68 Figure 14 4 Circuit Diagram For Axcess E 450 2 Of 2 ...
Page 73: ...Circuits OM 244 814 Page 69 245 131 F Part 2 Of 2 ...
Page 74: ...OM 244 814 Page 70 Figure 14 5 Circuit Diagram For Axcess E 675 1 Of 2 ...
Page 75: ...Circuits OM 244 814 Page 71 250 570 C Part 1 Of 2 ...
Page 76: ...OM 244 814 Page 72 Figure 14 6 Circuit Diagram For Axcess E 675 2 Of 2 ...
Page 77: ...Circuits OM 244 814 Page 73 250 570 C Part 2 Of 2 ...
Page 78: ...OM 244 814 Page 74 Figure 14 7 Circuit Diagram For Axcess E Module ...
Page 79: ...Circuits OM 244 814 Page 75 250 571 C ...
Page 80: ...OM 244 814 Page 76 Notes ...
Page 106: ...Notes ...