Instruction Manual
Page 6
3.0
Electrical and Air Requirements
CHAPTER 3
ELECTRICAL AND AIR REQUIREMENTS
Warning! Only a qualified electrician may connect the electrical power.
Preparation - World Power
1. Make sure the Power Supply is at 230v, 25amp, 50/60hz or 400v, 16amp, 50/60hz
and the Pressure Supply comes up to 120 psi (8.3 bar) when the machine is working.
2. Make sure the voltage and current is dedicated to the machine and to the above
specification.
3. An appropriate ground connection must be made to the ground terminal provided on
the machine.
4. Before operation of the machine be sure the surrounding area of the machine is free
of flammable debris. Only authorized persons should be in the area of the machine
while in use.
5. In the event of an emergency, press the Emergency Stop Button.
Electrical Supply
Due to the number of different style outlets available, the cord will not include a plug. It is recom-
mended that your electrician install a plug that is comparable to your style power outlet. You may
choose to have your power cord hard-wired into your Power Supply. It is recommended that
your electrician use a Junction Box with an ON/OFF switch. The Miller Weldmaster T600 requires
one of the following electrical requirements:
•25 Amp - Single phase - 230 Volts
•16 Amp - Single phase - 400 Volts
Shop Air Supply
The Miller Weldmaster T600 includes an In-Shop Air Supply Valve that allows quick connects
and disconnects to your shop air supply. Due to the number of different style airline connectors,
a male quick-connect is not included. You will want to select a male quick-connect with a ¼
inch NPT (National Pipe Thread) to match your female quick-connect. The Miller Weldmaster
T600 requires the following shop air requirements:
•Minimum of 5 cfm at 120 psi
•Not to exceed 140 liters/min at 8.3 Bar
•An in-line water and dirt separator