Millennia Media HV-316 page 8 of 18
If you have everything set correctly when Ælogic
opens, the icon of the HV-
316’s Unit ID
in the Unit
Status window will turn green. Double click on it to
open the Unit Status dialog box.
Set the IP address and click OK
You will lose the connection if you select an IP
Address other than 192.168.1.xxx
and will need
to change your computer
’s IP Address
to access the
network that you have chosen to use the HV-316
with after you configure all your HV-316s.
Dynamic Host Configuration Protocol (DHCP)
is
also an option for “IP Address”, but we don’t
recommend using it unless you are familiar with
networking and have the proper network hardware
that supports it.
Ethernet and MIDI control cannot be used
simultaneously
–
only one remote control protocol
can be used at a time in an HV-316 network.
The table below is a suggested addressing scheme.
IP Address
Unit ID
192.168.1.200
Host Computer
192.168.1.221
HV-316 ID 01
192.168.1.222
HV-316 ID 02
192.168.1.223
HV-316 ID 03
192.168.1.2nn
HV-316 ID nn
Default Settings
–
The HV-316 is shipped to
startup with the default settings:
•
All functions turned off (POL, PAD, 48V,
MUTE, SPLIT, SAFE, RBIN and HPF).
•
IP Address set to 192.168.1.221
•
Netmask 255.255.255.0
•
Unit ID 1