![MikroTik RouterOS v2.9 Reference Manual Download Page 603](http://html1.mh-extra.com/html/mikrotik/routeros-v2-9/routeros-v2-9_reference-manual_1794644603.webp)
averages, with short peak values ignored as likely read errors
Property Description
3.3v - +3.3V power line voltage
5v - +5V power line voltage
board-temp - temperature of the PCI area
core - CPU core voltage
cpu-temp - temperature of the CPU area
lm87-temp - temperature of the LM87 chip
state ( read-only: enabled | disabled ; default: disabled ) - the current state of health monitoring
(whether it is enabled or not)
state-after-reboot ( enabled | disabled ; default: disabled ) - the state of the health monitor after
the reboot
Notes
You cannot change state on the fly, just control, whether the health control will be enabled after
reboot
All themperature values are in Celsius degrees
Example
To check system health:
[admin@MikroTik] system health> print
core: 1.32
3.3v: 3.26
5v: 4.97
lm87-temp: -0.9
cpu-temp: -0.9
board-temp: -0.9
state: enabled
state-after-reboot: enabled
[admin@MikroTik] system routerboard health>
LED Management or RB200
Command name: :led
Description
The four user LEDs of the RouterBOARD 200 series can be controlled from user-space scripts.
Property Description
led1 ( yes | no ; default: no ) - whether the LED1 is on
led2 ( yes | no ; default: no ) - whether the LED2 is on
Page 589 of 695
Copyright 1999-2007, MikroTik. All rights reserved. Mikrotik, RouterOS and RouterBOARD are trademarks of Mikrotikls SIA.
Other trademarks and registred trademarks mentioned herein are properties of their respective owners.