3
Fault Repair
3.1
Motor Does Not React in the "Automatic" Setting or Always Runs
at High Speed
Cause
Low-pressure channel to the bag compartment is clogged.
Remedy
Fig. 7
A
Check the low-pressure channel in the dust compartment lid (040 Fig. 7, Pos.
1) for clogs.
Cause
The hose between the pressure sensor and the dust compartment is kinked or
damaged.
Remedy
A
Cover Frame Removal, 020 4.2.
A
Check the hose for damages, kinks or clogs; see 040 Fig. 5.
A
If necessary, replace the hose.
Descriptive Technical Documentation
040-6
DTD no. 41-8000
This information should not be duplicated or passed on without Miele approval. All rights reserved.
07.06.2013, US_am