Technical Information
51
S 500 & S 600 Canister Vacuums
Figure 030-9:
Cord Reel, Unwound
3. Clamp the cord reel to the body of the cord reel assembly to immobilize it.
See Figure 030-10. Failure to clamp the cord reel can allow it to rotate,
changing the spring tension and affecting operation. The reel can also
separate from the body, releasing the tension spring.
Always
clamp the
reel to the body before performing any cord repair.
Figure 030-10:
Cord Reel Clamped to Reel Assembly Body
4. Once the clamp is in place, remove the 2 T10 screws from the cord reel.
See Figure 030-11.
Figure 030-11:
Screws Securing Cord Reel