Technical Information
46
S 500 & S 600 Canister Vacuums
14. If there is 8.4 volts between pins 2 and 3 at the cap electronic, then check
for 0.4 volts between pins 1 and 2 and 1 and 3 at the cap electronic. If
there is not 0.4 volts between pins 1 and 2 and pins 1 and 3 at the cap
electronic, then the cap electronic is faulty. Replace it, following the
instructions in Section 030-4.12.
15. If there is 0.4 volts between pins 1 and 2 and pins 1 and 3 at the upper
electronic, then the connecting cable (power cord) has a broken
connection. Replace it, following the instructions in Section 030-4.4.
Figure 030-1:
Electronic Connections
Summary of Contents for S 500 Series
Page 1: ...TECHNICAL INFORMATION S 500 and S 600 Canister Vacuums 2011 Miele USA ...
Page 17: ...Technical Information 17 S 500 S 600 Canister Vacuums 010 Casing Bottom ...
Page 25: ...Technical Information 25 S 500 S 600 Canister Vacuums 020 Casing Top ...
Page 42: ...Technical Information 42 S 500 S 600 Canister Vacuums 030 Operating Unit S 51x S 61x shown ...
Page 58: ...Technical Information 58 S 500 S 600 Canister Vacuums 040 Motor ...
Page 61: ...Technical Information 61 S 500 S 600 Canister Vacuums 050 Suction Hose ...
Page 63: ...Technical Information 63 S 500 S 600 Canister Vacuums 055 Electro Suction Hose S 558 S 658 ...