Technical Information
65
S 500 & S 600 Canister Vacuums
3.5
Appliance Cannot Be Switched On
Cause:
Electronic in handle is defective.
Remedy:
Replace the suction hose with electronic; see Section 055-4.1.
Cause:
Poor contact between slip ring and electronic.
Remedy:
Replace the suction hose with electronic; see Section 055-4.1.
3.6
Power Level Cannot Be Adjusted
Cause:
Electronic in handle is defective.
Remedy:
Replace the suction hose with electronic; see Section 055-4.1.
Cause:
Poor contact between slip ring and electronic.
Remedy:
Replace the suction hose with electronic; see Section 055-4.1.
3.7
Electrobrush Cannot Be Selected
Cause:
Electronic in handle is defective.
Remedy:
Replace the suction hose with electronic; see Section 055-4.1.
Cause:
Poor contact between slip ring and electronic.
Remedy:
Replace the suction hose with electronic; see Section 055-4.1.
4 Service
4.1
Replacing the Suction Hose with Electronic
Danger!
For safety reasons the handle should not be dismantled as locking tabs
can become damaged. Safe and correct reassembly can then not be
ensured. To increase electrical safety, the hose connection at the handle
has been strengthened with a ring. Handles strengthened in this way
cannot be dismantled.
Only replace the suction hose as a complete assembly.
Summary of Contents for S 500 Series
Page 1: ...TECHNICAL INFORMATION S 500 and S 600 Canister Vacuums 2011 Miele USA ...
Page 17: ...Technical Information 17 S 500 S 600 Canister Vacuums 010 Casing Bottom ...
Page 25: ...Technical Information 25 S 500 S 600 Canister Vacuums 020 Casing Top ...
Page 42: ...Technical Information 42 S 500 S 600 Canister Vacuums 030 Operating Unit S 51x S 61x shown ...
Page 58: ...Technical Information 58 S 500 S 600 Canister Vacuums 040 Motor ...
Page 61: ...Technical Information 61 S 500 S 600 Canister Vacuums 050 Suction Hose ...
Page 63: ...Technical Information 63 S 500 S 600 Canister Vacuums 055 Electro Suction Hose S 558 S 658 ...